ICP-CC488 Installation Guide 7.0

Programming

 

 

EN 36

If you do not enter Installer’s Programming Mode first, connecting the CC891 Programming Key to the control panel when the programming key memory is blank corrupts the control panel’s memory. If this occurs, you must return the control panel to Bosch Security Systems, Inc. to unlock the control panel’s memory. A service fee will be charged.

7.3Programming Option Bits

When programming these locations, each location has four options. You can select one, two, three, or all four options for each location, but you can program only one value for the location. Calculate this value by adding the option bit numbers together.

Example

If you want to select Options 1, 2, and 4 for Location 177, add the numbers and program the sum. In this example, program a 7 in the location (1 + 2 + 4 = 7).

Table 35: Programming Option Bits Example

Option Description

1Allow dialer reporting functions

2Enable remote arming by telephone

4Enable answering machine bypass only when armed

8Enabled = Use Bell 103 for FSK format Disabled = CCITT V21 format

7.4Installer’s Programming Commands

You can use ten commands in Installer’s Programming Mode. To issue the command, enter the command number and press [#].

Table 36: Installer’s Programming Mode Commands

Command Function

959Test the programming key Refer to Section 7.4.1.

960Exit from Installer’s Programming Mode Refer to Section 7.4.2.

961Reset the control panel to factory defaults Refer to Section 7.4.3.

962Copy the control panel memory to the programming key

Refer to Section 7.4.4.

963Copy the programming key data to the control panel memory

Refer to Section 7.4.5.

964Erase the programming key Refer to Section 7.4.6.

965Set up domestic dialing format Refer to Section 7.4.7.

966Enable/disable the automatic stepping of locations during programming

Refer to Section 7.4.8.

999Display the software version number or control panel type

Refer to Section 7.4.9.

7.4.1Command 959 – Test the Programming Key

This command initiates a test of the programming key. You can use the CC891 Programming Key only with the ICP-CC488 Control Panel.

The programming key test is non-destructive, and any data in the programming key remains after the test is completed. One long beep indicates that the programming key test failed. Two beeps indicates a successful test.

If you remove the programming key before the test is finished, the programming key data becomes corrupt. Do not remove the programming key while the activity LED is lit or pulsing rapidly.

To test the programming key:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the remote codepad to indicate you entered Installer’s Programming Mode. The remote codepad displays the data stored in Location 000.

2.Connect the programming key to the PROGRAMMING KEY pins (next to the Auxiliary Module socket) at the top of the control panel printed circuit board.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 36
Image 36