ICP-CC488 Installation Guide 20.0

RF Information

 

 

EN 88

Figure 21: Connections for CP-5 Master Partitioned Codepad and CP-5 Area Addressable Codepad

1

– Data

5

– Master Partitioned

2

– CLK

 

Codepad

3

– +12 V

6

– Addressable Area

4

– GND

 

Codepad

 

 

Set the DIP Switches and program these locations for the two CP-5 Area Addressable (CP500A) codepads to function correctly.

1.Set DIP Switch 1 on the back of the remote codepad for Area 1 to the ON position (refer to Figure 20 on page 87).

2.Set DIP Switch 2 on the back of the remote codepad for Area 2 to the ON position.

3.Select Option 2 in Location 500 (refer to Section 19.3.1 Partitioning Options 1 on page 85).

4.For Output 1, program Location 436 to 6 and Location 437 to 1 (refer to page 75).

Figure 22: Connections for Two CP-5 Area Addressable Codepads

1 –

Data

4 –

GND

2 –

CLK

5 – Area 1 Codepad

3 –

+12 V

6 –

Area 2 Codepad

 

 

 

 

20.0RF Information

20.1RF Option Bit

Location 599

Default 0

1Sound siren on RF receiver fail

2Sound siren on RF receiver tamper/jamming

4Unseal zone that fails supervision (if supervision enabled)

8Enable RF jamming monitoring

1 – Sound Siren on RF Receiver Fail

If this option is selected, the horn speaker, piezo, and strobe operate when the RF receiver fails to communicate with the control panel.

2 – Sound Siren on RF Tamper/Jamming

If this option is selected, the horn speaker, piezo, and strobe operate when the tamper switch on the receiver becomes open circuit or the receiver picks up jamming signals from an RF device.

4 – Unseal Zone that Fails Supervision

If a wireless zone device fails to send a signal within the RF Supervision Time programmed in Location 393 (refer to Section 15.8) the codepad zone indicator lights as unsealed.

Bosch Security Systems, Inc. 12/08 F01U089457-02