3.12Fault Analysis Mode

When a system fault occurs, the FAULT or MAINS indicator flashes and the codepad beeps once per minute.

If the AC MAINS supply fails, the MAINS indicator flashes until the AC MAINS supply is restored. Press [AWAY] once to acknowledge the fault and stop the codepad from beeping once every minute.

To enter Fault Analysis Mode to determine a system fault other than the AC MAINS supply:

1.Press and hold [5] until two beeps sound.

The FAULT indicator remains lit and the STAY and AWAY indicators flash.

The lit zone indicators indicate the type of fault that occurred. Refer to Table 15 on page 20.

2.If necessary, hold down the button corresponding to the indicator to further determine the fault. Refer to Table 15 on page 20.

3.To exit from Fault Analysis Mode, press [AWAY].

The STAY and AWAY indicators are extinguished and the FAULT indicator remains lit.

3.13Fault Descriptions

1 – System Fault

The system FAULT indicator lights when any of the faults listed in Table 14 on page 19 occurs. In Fault Analysis Mode, hold down [1] to determine the fault that occurred.

2 – RF Low Battery

This fault occurs when a wireless zone (1 to 16) reports a low battery condition. In Fault Analysis Mode, hold down [2] until two beeps sound to light the indicator for the zone that reported the fault.

3 – Tamper Fail

This fault occurs when a zone becomes open circuit. In Fault Analysis Mode, hold down [3] until two beeps sound to display the zone that reported the fault.

4 – Sensor Watch Fault

This fault occurs when one or more detection devices fails to detect an intrusion while disarmed for the time period programmed in Locations 476 and 477 (refer to Section 15.5 Zone Status – Sensor Watch Reports on page 78). The fault clears when the faulted zone detects movement and is reset.

In Fault Analysis Mode, hold down [4] until two beeps sound to show the zone that reported the fault.

5 – RF Sensor Watch Fault

This fault occurs when one or more wireless detection devices fails to detect an intrusion while disarmed state for the time programmed in Locations 476 and 477 (refer to Section 15.5 Zone Status – Sensor Watch Reports on page 78). The fault clears when the faulted zone detects movement and is reset.

In Fault Analysis Mode, hold down [5] until two beeps sound to show the zone that reported the fault.

6 – Communication Fail

A communication failure registers when the control panel fails to communicate with the receiving party (for example, monitoring company, mobile phone, or pocket pager).

The communication fault clears when the control panel successfully reports to the receiving party.

In Fault Analysis Mode, hold down [6] until two beeps sound to show which communication fault occurred: 1 – Receiver 1; 2 – Receiver 2.