ICP-CC488 Installation Guide 18.0

System and Consumer Options

 

 

EN 80

For partitioned ICP-CC488 Control Panels, both areas are automatically disarmed at the same time each day.

17.14 Kiss-Off Wait Time

Location 490

Default 3

Increments of 500 ms (500 ms to 8 sec)

This location sets the time the control panel waits for acknowledgment before resending a report. This timer applies only to the 4 + 2 Express Format.

17.15 Speaker Beep Volume

Location 491

Default 13

0No beeps

15 Loudest beeps

This location allows you to adjust the speaker volume for remote radio operation.

17.16 System Time

Location 901 to 904

 

Location

Default

Hour of the day (tens digit)

901

0

Hour of the day (units digit)

902

0

Minute of the day (tens digit)

903

0

Minute of the day (units digit)

904

0

The ICP-CC488 Control Panel has a real-time 24- hour clock you must set during installation. Set this time in 24-hour HHMM format (for example, program 10:30 PM as 2230). You must reset the System Time every time the system is powered down.

17.17 System Date

Location 905 to 910

 

Location

Default

Day of the month (tens digit)

905

0

Day of the month (units digit)

906

1

Month of the year (tens digit)

907

0

Month of the year (units digit)

908

1

Current year (tens digit)

909

0

Current year (units digit)

910

1

The ICP-CC488 Control Panel has a real-time

12-month calendar you must set during installation. Set the date in DDMMYY format (for example, program 1 January 2004 as 010104). You must reset the System Date every time the system is powered down.

To set the date and time:

1.Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day, and MM minute of the day) and press [AWAY]. Use 24:00 hour format when programming the hour of the day.

Two beeps sound and the STAY and AWAY indicators are extinguished. If a long beep sounds, there was an error when you entered the date and time.

Example

To set the date and time for the 1st January 2004 at 10:30 PM, enter:

[2 5 8 0 6][AWAY][0 1 0 1 0 4 2 2 3 0][AWAY]

18.0 System and Consumer Options

The locations in this section have up to four options. You can select any combination of these options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 7.3 Programming Option Bits on page 36 for more information.

18.1System Options 1

Location 492

1Bosch Security Systems, Inc. smart lockout allowed

2 Horn speaker monitor

4 Strobe indications for radio arm/disarm

8Assign Button 4 on transmitter to operate STAY Mode 1

1 – Smart Lockout Allowed

This feature allows the control panel to remove any zones that are programmed for lockout dialer from the lockout list when the sirens are running. This feature allows a monitoring station to receive zone alarm reports from previously locked out zones during siren time. Refer to Section 14.3.5 Zone Options 1 on page 61 for information on programming zones for lockout dialer and lockout siren.

Refer to Section 14.5 Swinger Shutdown Count for Dialer on page 64 to program the number of times the zone can report before being locked out.

2 – Horn Speaker Monitor

If this option is selected, the control panel detects when the horn speaker is disconnected from the speaker terminals. The FAULT indicator lights when the horn speaker is disconnected and is extinguished when the horn speaker is reconnected.

If an output is required to operate when the horn speaker is disconnected, use Output Event Type 1,6 Horn Speaker Monitor Fail (refer to page 72 for more information).

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 80
Image 80
Bosch Appliances ICP-CC488 manual System and Consumer Options