Bosch Appliances manual ICP-CC488| Installation Guide, Zone Information, En

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 60
Image 60
Manual background

ICP-CC488 Installation Guide 14.0

Zone Information

 

 

EN 60

14.3.2Zone Types

The zone types are listed in Table 48.

Table 48:

Zone Types

 

 

 

 

Zone Type

Description

0

Instant

1

Handover

2

Delay-1

3

Delay-2

4

Reserved

5

Reserved

6

24-Hour Medical

7

24-Hour Panic

8

24-Hour Holdup

9

24-Hour Tamper

10

Reserved

11

Keyswitch

12

24-Hour Burglary

13

24-Hour Fire

14

Chime Only

15

Not used

0 – Instant Zone

An Instant Zone (Contact ID Event Code 130) immediately sounds the sirens and operates the dialer if it is unsealed after the Exit Timer expires.

If an Instant Zone is not restored when the time the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

1 – Handover Zone

A Handover Zone (Contact ID Event Code 130) acts as an Instant Zone if it is activated by itself. If a Handover Zone is activated after a Delay Zone, the remaining Delay Time is handed over from the Delay Zone to the Handover Zone.

Handover can be sequential or non-sequential. The default settings is sequential handover. You can disable sequential handover by disabling Option 8 in Location 494 (refer to Section 18.3 System Options 3 on page 81).

If a Handover Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

2 – Delay-1 Zone

A Delay-1 Zone (Contact ID Event Code 130) has a delay time determined by the value in Locations 466 and 467 (refer to Section 17.2 Entry Timer 1 on page 78). After Entry Time expires, the system activates an alarm.

If a Delay-1 Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

3 – Delay-2 Zone

A Delay-2 Zone (Contact ID Event Code 130) has a delay time determined by the value in Locations 468 and 469 (refer to Section 17.3 Entry Timer 2 on page 78). After Entry Time expires, the system activates an alarm.

If a Delay-2 Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

6 – 24-Hour Medical Zone

A 24-Hour Medical Zone (Contact ID Event Code

100)is always ready to activate the dialer, horn speaker, bell, and strobe, whether the system is armed or disarmed. A Medical Report is transmitted to the base station receiver. A 24-Hour Medical Zone does not send a Restore Report until the zone is restored.

7 – 24-Hour Panic Zone

A 24-Hour Panic Zone (Contact ID Event Code 120) is always ready to activate the dialer, horn speaker, bell, and strobe, whether the system is armed or disarmed. A Panic Report is transmitted to the base station receiver. A 24-Hour Panic Zone does not send a Restore Report until the zone is restored.

8 – 24-Hour Holdup Zone

A 24-Hour Holdup Zone (Contact ID Event Code

122)is always ready to activate the dialer, horn speaker, bell, and strobe, whether the system is armed or disarmed. If you want the holdup alarm to be silent, select Option 4 in the first Zone Options location (refer to Section 14.3.5 Zone Options 1 on page

61).A 24-Hour Holdup Zone does not send a Restore Report until the zone is restored.

9 – 24-Hour Tamper Zone

A 24-Hour Tamper Zone (Contact ID Event Code

137)is always ready to activate the dialer, horn speaker, bell, and strobe, whether the system is armed or disarmed. A 24-Hour Tamper zone does not send a Restore Report until the zone is restored.

11 – Keyswitch Zone

Use a Keyswitch Zone to connect a keyswitch to operate the system. Refer to Section 14.3.6 Keyswitch Zone Options for information on programming this zone type. User Code 16 is reported when arming and disarming using this method of operation. Programming the priority level of User Code 16 also affects the operation of the Keyswitch Zone. Refer to Section 13.3 User Code Priority for more information.

12 – 24-Hour Burglary Zone

A 24-Hour Burglary Zone (Contact ID Event Code

133)is always ready to activate the dialer, horn speaker, bell, and strobe, whether the system is armed or disarmed. A 24-Hour Burglary zone does not send a Restore Report until the zone is restored.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 60
Image 60
Bosch Appliances manual ICP-CC488| Installation Guide, Zone Information, En