Bosch Appliances manual ICP-CC488 Installation Guide, System Functions, En

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 24
Image 24
Manual background

ICP-CC488 Installation Guide 5.0

System Functions

 

 

EN 24

Table 21: Codepad Indicators When Changing Phone Numbers

 

 

 

Zone Indicators

 

 

MAINS

Digit

1

2

3

4

5

6

7

8

Indicator

0

 

 

 

 

 

 

 

 

X

1X

2X

3

 

X

 

4

 

X

 

5

 

X

 

 

 

 

 

6

 

 

X

7

 

 

X

8

 

 

X

 

 

 

 

9

X

 

X

*

X

 

X

#

X

 

X

 

 

 

 

Pause

 

X

X

Break

 

X

X

 

 

 

 

15

 

X

X

5.1.4Change Telco Arm/Disarm Sequence

This function allows you to program the call forward sequence to automatically operate when you arm the system in AWAY Mode. This feature is available only if the call forward option is available from your telecommunication provider.

Telco Arm Sequence

This option allows you to program the Call Forward

Immediate On sequence or Call Forward – No Answer sequence that automatically operates when you arm the system in the AWAY Mode..

The examples provided for this feature apply only to Australia.

Call Forward – Immediate On

You can redirect calls to anywhere in Australia, including mobiles, pagers, and answering services. When this Call Forward option is turned on, your telephone does not ring.

Call Forward – No Answer

If your telephone is not answered within 20 sec, this feature redirects the incoming call to another number anywhere in Australia. You can still make outgoing calls.

Telco Disarming Sequence

This option allows you to automatically disable the call forward sequence when you disarm the system.

Table 22: Telco Arm/Disarm Dialing Digits

Digit

Number to

Digit

Number to

Required

Program

Required

Program

0

0

8

8

1

1

9

9

2

2

 

 

3

3

*

[STAY]1

4

4

#

[STAY]2

5

5

4 sec pause

[STAY]3

6

6

break

[STAY]4

7

7

 

 

To program the telco arming sequence:

1.Enter the Installer Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [1][AWAY] to change the telco arming sequence. Three beeps sound.

If a call forwarding sequence is already programmed, the sequence is displayed one digit at a time using the remote codepad indicators. Refer to Table 21 on page 24 for the indicators and their meanings.

If no call forward sequence is programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the call forward sequence is displayed.

3.Enter the desired call forward sequence.

For example, program [* 6 1][phone number][#] for the call forward – no answer sequence, or [* 2 1][phone number][#] for the call forward – immediate sequence.

Remember that when you program a * in the telco arm sequence, you enter [STAY][1]. When you program the # in the telco arm sequence, you enter [STAY][2].

4.Press [STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

Example

If you want to automatically divert all unanswered incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter:

[1 2 3 4 3][AWAY][1][AWAY][STAY] [1 6 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]

You can suspend the telco arming sequence at any time. To disable the telco arming sequence:

Enter the Installer Code and press [3][AWAY][1] [AWAY][STAY][4][AWAY].

Bosch Security Systems, Inc. 12/08 F01U089457-02