ICP-CC488 Installation Guide 14.0

Zone Information

 

 

EN 58

Figure 13: Split EOL Resistors Using Two N/O Contacts

1

2

4

5

3

67

88

1

– +12 V

5

– EOL 6K8

2

– Zone Input

6

– EOL 1K5

3

– Zone

7

– EOL 4K7

4

– EOL 3k3

8

– N/O

14.3Zone Programming

The programming information for each zone is stored in seven locations divided into three groups. The first three locations determine how the zone operates, the next two locations set up a number of zone options, and the last two locations store the dialer reporting information for the zone.

Zone Operating Information

These locations store the Zone Type (for example, Delay-1, Instant, or 24-Hour), the Zone Pulse Count, and the Zone Pulse Count Time. The Zone Pulse Count specifies the number of times the zone must activate within the time specified in the Zone Pulse Count Time. Refer to Sections 14.3.2 Zone Types,

14.3.3Zone Pulse Count, and 14.3.4 Zone Pulse Count Time on pages 59 through 61 for more information.

Zone Options

These two locations allow you to select from a number of options. Refer to Sections 14.3.5 Zone Options 1 on page 61 and 14.3.7 Zone Options 2 on page 63 for more information.

Zone Reporting Information

This information includes the locations for the Zone Report Code and the Zone Dialer Options.

The Zone Report Code determines if the control panel sends Alarm Reports for the zone. Refer to Section 14.3.8 Zone Report Code on page 64 for more information.

The Zone Dialer Options location enables you to specify how a zone reports to a base station receiver. Refer to Section 14.3.9 Zone Dialer Options on page 64 for more information.

14.3.1 ICP-CC488 Zone Defaults

Location 267 to 378

 

Location

Default

Zone #01 (Default = Delay–1)

 

 

Zone Type

267

2

Zone Pulse Count

268

0

Zone Pulse Count Time

269

0

Zone Options 1

270

1

Zone Options 2

271

14

Report Code

272

1

Dialer Options

273

1

Zone #02 (Default = Handover)

 

 

Zone Type

274

1

Zone Pulse Count

275

0

Zone Pulse Count Time

276

0

Zone Options 1

277

1

Zone Options 2

278

14

Report Code

279

1

Dialer Options

280

1

Zone #03 (Default = Handover)

 

 

Zone Type

281

1

Zone Pulse Count

282

0

Zone Pulse Count Time

283

0

Zone Options 1

284

1

Zone Options 2

285

14

Report Code

286

1

Dialer Options

287

1

Zone #04 (Default = Handover)

 

 

Zone Type

288

1

Zone Pulse Count

289

0

Zone Pulse Count Time

290

0

Zone Options 1

291

1

Zone Options 2

292

14

Report Code

293

1

Dialer Options

294

1

Zone #05 (Default = Instant)

 

 

Zone Type

295

0

Zone Pulse Count

296

0

Zone Pulse Count Time

297

0

Zone Options 1

298

1

Zone Options 2

299

14

Report Code

300

1

Dialer Options

301

1

Zone #06 (Default = Instant)

 

 

Zone Type

302

0

Zone Pulse Count

303

0

Zone Pulse Count Time

304

0

Zone Options 1

305

1

Zone Options 2

306

14

Report Code

307

1

Dialer Options

308

1

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 58