12.2Dialer Options 2

ICP-CC488 Installation Guide 12.0

Dialer Options

 

 

EN 53

2 – Remote Arming by Telephone Allowed

If you select this option, you can remotely arm the system using a standard telephone by pressing [*] on your touch-tone telephone. Refer to Section 6.0 Remote Arming by Telephone on page 34 for more information. Forced arming is automatically assumed when this feature is used. Refer to Section 14.3.7 Zone Options 2 on page 63 for more information on forced arming.

Remote arming by telephone is not affected by whether remote functions are enabled or disabled. Refer to Section 8.2 Alarm Link Options on page 41 for programming the number of rings before the control panel answers an incoming call.

4 – Answering Machine Bypass Only When Armed

Select this option to enable the Answering Machine Bypass feature when the system is armed. When the system is disarmed, the control panel does not answer any incoming calls. This option is beneficial in high telephone traffic installations where the control panel could answer an incoming call. Refer to Section 8.2 Alarm Link Options on page 41 to program Answering Machine Bypass.

8 – Use Bell 103 for FSK Format (Disabled=CCITT

V21)

If this option is selected, the control panel uses the BELL 103 transmission frequency at 300 baud. If this option is not selected, the control panel uses the CCITT V21 transmission frequency at 300 baud.

12.2Dialer Options 2

Location 178

Default 0

1Open/Close Reports only if previous alarm

2Open/Close Reports for STAY Mode 1 and STAY Mode 2

4Delay siren until transmission complete

8Extend handshake wait time from 30 sec to 60 sec

1 – Open/Close Reports Only if Previous Alarm

When selected, an Opening Report is transmitted to the base station receiver when the system is disarmed after an alarm occurred. When the system is armed, a Closing Report is transmitted. An Opening or Closing Report does not report again until the system registers another alarm.

Open/Close Reports must be enabled in Locations 401 and 402 (refer to Section 15.13 Open/Close Reports on page 65) for this option to work.

For a partitioned ICP-CC488 Control Panel, an Open/Close Report is sent only for the area in which the alarm occurred.

If the system is disarmed when an alarm occurs, only a Closing Report is sent the next time the system is armed.

A User Code with a priority set to Always Send Open/Close Reports overrides this feature (Open/Close Reports are always sent for that User Code).

2 – Open/Close Reports for STAY Mode 1 and STAY Mode 2

Select this option if Open and Close Reports are required when the system is armed in STAY Mode 1 or STAY Mode 2.

If this option is selected, a Partial Close Report (Contact ID Event Code 456) is sent when the system is armed in STAY Mode 1 or STAY Mode 2.

Open/Close Reports must be enabled in Locations 401 and 402 (refer to Section 15.13 Open/Close Reports on page 65) for this option to work.

4 – Delay Siren until Transmission Complete

If this option is selected, the EDMSAT, horn speaker, bell, and strobe outputs are not activated until after the control panel sends the message and the base station receiver sends a kiss-off back to the control panel. If multiple messages are transmitted, the sirens are activated after the last kiss-off is sent.

If a Codepad Panic, Codepad Fire, or Codepad Medical Alarm is activated, the EDMSAT, horn speaker, bell, and strobe outputs operate immediately.

8 – Extend Time to Wait for Handshake from 30 to 60 Sec

By default, the control panel waits approximately 30 sec for receipt of a valid handshake tone after it dials the monitoring station. The handshake tone indicates to the control panel that it reached the monitoring station and can now transmit its messages. Selecting this option extends this wait time from 30 sec to 60 sec.

12.3Dialer Options 3

Location 179

1Set DTMF dialing pulses to 1 digit per sec

2 Lockout Telephone Line Fail Alarm

4 Change decadic dialing to 60/40

8 Reserved

1 – Set DTMF Dialing Pulses to 1 Digit/Sec

If this option is not selected, the Australian DTMF dialing format dials at 5 digits per sec (that is, 100 ms tone, 100 ms pause, 100 ms tone, 100 ms pause).

If this option is selected, the Australian DTMF dialing format dials at the rate of 1 digit per sec (that is, 500 ms tone, 500 ms pause).