The alarm memory plays back in this order:

Table 33: Event Memory Playback

Sequence

Indication

Event

1

All indicators off

System disarmed

 

except MAINS

 

2

Zone 4 and AWAY

Alarm in Zone 4

 

indicators light

 

3

Zone 3 and AWAY

Alarm in Zone 3

 

indicators light

 

4

AWAY indicator

System armed in

 

lights

AWAY Mode

Each event is indicated by a beep and a lit indicator. Resetting a disarmed 24-Hour Alarm is indicated by a beep only.

After the last event, three beeps sound to indicate the end of playback. You can stop the replay at any time by pressing [AWAY].

If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.

If the control panel is powered down, the memory of all events is saved.

If an ICP-CC488 Control Panel is partitioned, only ten events per area play back.

5.3User Code Functions

5.3.1Arm or Disarm Both Areas at the Same Time

This User Code function operates only with partitioned ICP-CC488 systems and allows User Codes allocated to both Area 1 and Area 2 to arm or disarm both areas at the same time.

This feature allows a user to arm or disarm the system by pressing one extra button rather than entering a code twice. You can use either the CP5 Area Addressable Codepad (ICP-CP500A) or the Master Partitioned Codepad (ICP-CP500P) with this function. To enable this feature, select Option 2 in Location 501 (refer to Section 19.3.2 Partitioning Options 2).

To arm or disarm both areas at the same time:

Enter your User Code and press [0][AWAY]. Two beeps sound and both areas are armed or disarmed from AWAY Mode.

5.4Hold-Down Functions

Hold-down functions allow easy activation of specific operations. When you hold down a button for 2 sec, two beeps sound and the corresponding function operates. The hold-down functions are listed below.

5.4.1Arm the System in AWAY Mode

Holding down [#] until two beeps sound arms the system in AWAY Mode. This hold-down function operates only if you select Option 2 in Location 497 (refer to Section 18.6 Consumer Options 2 on page 83).

This hold down function does not work if you are using an ICP-CP5 Master Partitioned codepad (CP500P) with a partitioned ICP-CC488 Control Panel.

If you are using an ICP-CP5 Area Addressable Codepad (ICP-CP500A) with a partitioned ICP-CC488 Control Panel, this function arms the corresponding area in AWAY Mode.

5.4.2Arm the System in STAY Mode 1

Holding down [*] until two beeps sound arms the system in STAY Mode 1. This hold-down function operates only if you select Option 2 in Location 497 (refer to Section 18.6 Consumer Options 2 on page 83).

If there was no alarm during the armed cycle, holding down [*] a sec time disarms the system from STAY Mode 1. To enable single button disarming from STAY Mode 1 using this hold-down function, select Option 4 in Location 497.

If an alarm occurred or entry warning was activated, a valid User Code is required to disarm the system.

Refer to Section 14.3.7 Zone Options 2 on page 63 for information on programming each zone to be automatically isolated in STAY Mode 1.

This hold-down function does not work if you are using an ICP-CP5 Master Partitioned Codepad (ICP-CP500P) with a partitioned ICP-CC488 Control Panel.

If you are using an ICP-CP5 Area Addressable Codepad (ICP-CP500A) with a partitioned ICP-CC488 Control Panel, this function arms the corresponding area in STAY Mode1.

5.4.3Arm the System in STAY Mode 2

Holding down [0] until two beeps sound arms the system in STAY Mode 2. This hold-down function operates only if you select Option 2 in Location 497 (refer to Section 18.6 Consumer Options 2 on page 83).

If no alarm occurred during the armed cycle, holding down [0] a sec time disarms the system from STAY Mode 2. To enable single button disarming from STAY Mode 2 using this hold-down function, select Option 4 in Location 497.

If an alarm occurred or entry warning was activated, a valid User Code is required to disarm the system.