Bosch Appliances manual ICP-CC488| Installation Guide, Programming Sheets, En

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 106
Image 106
Manual background

ICP-CC488 Installation Guide 25.0

Programming Sheets

 

 

EN 106

Codepad Panic Report

Location

405 to 406

Refer to page 67

Default

7 15

 

 

 

Codepad Fire Report

Location

407 to 408

Refer to page 68

Default

7 14

Codepad Medical Report

Location

409 to 410

Refer to page 68

Default

7 13

 

 

 

Codepad Reporting Options

Location

411

Refer to page 68

0

No report required

 

 

 

 

1

Receiver 1

 

2

Receiver 2

 

4

Receiver 1 and 2

 

8

Receiver 2 only when Receiver 1 fails

System Status – AUX Power Supply Fail Report

Location

412 to 413

Refer to page 68

Default

10 3

System Status – AUX Power Supply Fail Restore Report

Location

414 to 415

Refer to page 68

Default

10 8

System Status – AC Fail Report

Location

416 to 417

Refer to page 68

Default

10 2

 

 

 

System Status – AC Fail Restore Report

Location

418 to 419

Refer to page 68

Default

10 7

System Status – Low Battery Report

Location

420 to 421

Refer to page 69

Default

10 1

 

 

 

System Status – Low Battery Restore Report

Location

422 to 423

Refer to page 69

Default

10 6

System Status – Access Denied

Location

424 to 426

Refer to page 69

Default

 

6 7 12

Location 424

Code retries

 

Location 425

Reporting code – tens digit

Location 426

Reporting code – units digit

System Status Reporting Options

Location

427

Refer to page 69

0

No report required

 

1

Receiver 1

 

2

Receiver 2

 

4

Receiver 1 and 2

 

8

Receiver 2 only when Receiver 1 fails

Test Reporting Time

Location

 

428 to 434

 

Refer to page 69

Default

 

0

0 0

0 7 1 0

Location 428

Hour of the day – tens digit

 

Location 429

Hour of the day – units digit

 

Location 430

Minute of the day – tens digit

Location 431

Minute of the day – units digit

Location 432

Test Report code – tens digit

Location 433

Test Report code – units digit

Location 434

Repeat interval in days

 

 

Test Reporting Dialer Options

Location

 

435

 

Refer to page 70

0No report required

1 Receiver 1

2 Receiver 2

4 Receiver 1 and 2

8 Receiver 2 only when Receiver 1 fails

Output Configurations

Location

 

436 to 465

 

 

Refer to page 70

Output 1

 

Locations 436 to 441

Default for horn speaker

 

 

1

14

0

0

0

0

Output 2

 

Locations 442 to 447

Default for Fire Alarm

 

 

2

7 10

2

1

5

verification

 

 

 

 

 

 

 

 

Strobe

 

Locations 444 to 453

Default for strobe (reset in 8 hr)

 

2 0

6

4

0

8

Relay

 

Locations 454 to 459

Default for sirens running

 

 

1

15

1

0

0

0

Codepad

 

Locations 460 to 465

Default for entry/Exit Warning

0 13

2

1

0 1

and Delay Alarm

 

 

 

 

 

 

 

 

Outputs are programmed with four parameters in six locations:

Event Type

Polarity

Time Base

Time Multiplier

 

 

 

 

 

 

Entry Time 1

Location

 

466 to 467

 

Refer to page 78

Default

 

4 1

Location 466

Increments of 1 sec (0 to 15 sec)

Location 467

Increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

Entry Time 2

Location

 

468 to 469

 

Refer to page 78

Default

 

8 2

Location 468

Increments of 1 sec (0 to 15 sec)

Location 469

Increments of 16 sec (0 to 240 sec)

Exit Time

Location

 

470 to 471

 

Refer to page 78

Default

 

12 3

Location 470

Increments of 1 sec (0 to 15 sec)

Location 471

Increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 106
Image 106
Bosch Appliances manual ICP-CC488| Installation Guide, Programming Sheets, En