| Alarm Link Software |
|
|
EN 41
•Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).
•Disable Option 1 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).
The control panel is set so the client controls when a remote connection is established.
To dial the remote computer:
Press and hold [6] until two beeps sound on the remote codepad.
8.1.2Remote Connection without Callback Verification
Remote connect without callback verification is useful if you must perform Upload/Download functions from multiple locations.
There are two methods to disable callback verification. Using this feature reduces the security of the control panel.
Method One
Method one allows you to call the control panel from any remote location without the control panel calling back to the computer to establish a link. When using this method, the customer cannot initiate a modem call by holding down [6].
To program method one:
1.Program Locations 159 to 174 for the Call Back Telephone Number to 0 (refer to Section 11.9 on page 51).
2.Select Option 1 and disable Option 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).
The control panel allows a connection of the first call without calling the remote computer back.
Method Two
Method two allows you to program a callback telephone number so that the customer can still initiate a modem call when required. When you call the control panel from a remote location using the computer, the control panel does not call back the remote computer to establish a link.
To program method two:
1.Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).
2.Select Option 1 and disable Option 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).
The control panel allows a connection of the first call without calling back the remote computer to make contact. It allows the customer to initiate a modem call by holding down [6].
8.1.3Remote Connection with Callback Verification
Remote connect with callback verification offers the highest degree of data security by incorporating a
The first level is provided because the Installer Code and the Subscriber ID Number must match those of the control panel. The sec level of security exists because the control panel calls the programmed callback telephone number to establish the valid connection.
To program the control panel for remote connection with callback verification:
1.Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).
2.Select Options 1 and 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).
8.1.4Direct Connection
The direct connect feature gives the installer a simple method to program the
To use the direct connect feature, connect the CC808 Direct Link Cable between the correct serial port on your IBM or compatible computer and the auxiliary module socket on the control panel.
To use the direct connect feature, it is not necessary to select Option 1 Location 180. The direct connect feature ignores this option.
8.2Alarm Link Options
Location 180
1Enable upload/download using Alarm Link
2 Enable Alarm Link call back
4 Terminate Alarm Link connection on alarm
8 Reserved
When programming these locations, you can select any of four options. You can select any combination of the options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 7.3 Programming Option Bits on page 36 for more information.
1 – Enable Upload/Download Using Alarm Link
Select this option to use the CC816 Alarm Link Software to program the control panel remotely. The control panel does not respond to the Alarm Link Software if this option is not selected. Refer to Section
8.0Alarm Link Software on page 40 for more information.