ICP-CC488 Installation Guide 25.0

Programming Sheets

 

 

EN 104

Zones

Location

267 to 378

 

Refer to page 58

Zone 1

Locations 267 to 273

Default

2

0

0

1

14

1

1

Zone 2

Locations 274 to 280

Default

1

0

0

1

14

1

1

Zone 3

Locations 281 to 287

Default

1

0

0

1

14

1

1

Zone 4

Locations 288 to 294

Default

1

0

0

1

14

1

1

Zone 5

Locations 295 to 301

Default

0

0

0

1

14

1

1

Zone 6

Locations 302 to 308

Default

0

0

0

1

14

1

1

Zone 7

Locations 309 to 315

Default

0

0

0

1

12

1

1

Zone 8

Locations 316 to 322

Default

9

0

0

1

12

1

1

Zone 9

Locations 323 to 329

Default

15

0

0

1

14

1

1

Zone 10

Locations

330 to 336

Default

15

0

0

1

14

1

1

Zone 11

Locations 337 to 343

Default

15

0

0

1

14

1

1

Zone 12

Locations 344 to 350

Default

15

0

0

1

14

1

1

Zone 13

Locations 351 to 357

Default

15

0

0

1

14

1

1

Zone 14

Locations 358 to 364

Default

15

0

0

1

14

1

1

Zone 15

Locations

365 to 371

Default

15

0

0

1

14

1

1

Zone 16

Locations 372 to 378

Default

15

0

0

1

14

1

1

Each zone contains seven locations. The first three locations determine how the zone operates:

Zone Type

Zone Pulse

Zone Pulse

 

Count

Count Time

 

 

 

The next two locations contain zone options:

Zone Options 1

Zone Options 2

 

 

The last two locations contain reporting information:

Report Code

Dialer Options

 

 

Zone Types

These are the zone types available:

Zone Type

Description

0

Instant

1

Handover

2

Delay-1

3

Delay-2

4

Reserved

5

Reserved

6

24-Hour Medical

7

24-Hour Panic

8

24-Hour Holdup

9

24-Hour Tamper

10

Reserved

11

Keyswitch

12

24-Hour Burglary

13

24-Hour Fire

14

Chime only

15

Zone not used

Zone Pulse Count Settings

Program the pulse count settings for each zone from 0 to 15.

Zone Pulse Count Time

Zone pulse count time is the time frame or period over which the number of pulses must register.

20 ms Loop Response

150 ms Loop Response

Option

Time (sec)

Option

Time (sec)

0

0.5

8

20

1

1

9

30

2

2

10

40

3

3

11

50

4

4

12

60

5

5

13

90

6

10

14

120

7

15

15

200

 

 

 

 

Zone Options 1

Option

Description

1

Lockout siren/lockout dialer

2

Delay alarm reporting

4

Silent alarm

8

Sensor watch

Zone Options 2

 

 

Option

Description

1

Isolated in STAY Mode 1

2

Zone isolation allowed

4

Forced arming allowed

8

Enable Zone Restore Report

 

 

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 104
Image 104
Bosch Appliances ICP-CC488 manual Zones, Zone Pulse Count Settings