Table 42: 4 + 2 Transmission Code

ICP-CC488 Installation Guide 10.0

Dialer Reporting Formats

 

 

EN 45

Table 42: 4 + 2 Transmission Code

Descriptions

Code Description

SSSS Subscriber ID Number

AAlarm

CH

Channel Number1

0Zero

TTrouble

BBypass

EAC Fail Code 1st digit

AC

AC Fail Code 2nd digit

LLow Battery Code 1st digit

L

B

Low Battery Code 2nd digit

OOpen

CClose

UUser Number

RAlarm Restore Code

TR

Trouble Restore Code

BR

Bypass Restore Code

E

AC Fail Restore Code 1st digit

R

 

ACR

AC Fail Restore Code 2nd digit

L

Low Battery Restore Code 1st digit

R

 

L

Low Battery Restore Code 2nd digit

BR

 

DDuress Code 1st digit

D

0

Duress Code 2nd digit

PPanic Code 1st digit

P

Panic Code 2nd digit

CH

 

TE

Test Code

10=Zone 16, 1=Zones 1 through 15. Some receivers might need to have parameters set to 0 for Zone 16

10.1.5Basic Pager Reporting Format

Although Basic Pager Format requires some interpretation of the numbers that appear on the display, it is possible to differentiate among 1000 different control panels if a number of control panels report to the one pager.

To set up Receiver 1 for basic pager reporting:

1.Program the Basic Pager’s access telephone number in Locations 000 to 015 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 49).

2.Program the Subscriber ID Number in Locations 034 to 039 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 50).

3.Select the Pager Handshake option (5) in Location 032 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 49).

4.Program the Basic Pager Format option (5) in Location 033 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 50).

To set up Receiver 2 for basic pager reporting:

1.Program the Basic Pager’s access telephone number in Locations 040 to 055 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 49).

2.Program the Subscriber ID Number in Locations 074 to 079 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 50).

3.Select the Pager Handshake option (5) in Location 072 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 49).

4.Program the Basic Pager Format option (5) in Location 073 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 50).

The example in Figure 9 on page 47 shows:

A transmission from Subscriber ID Number 5678

Zone 2 is in alarm

Zone 3 is manually isolated

The system is armed

The Panic Zone is normal

The AC is connected

There is no fault condition.

Bosch Security Systems, Inc. 12/08 F01U089457-02