Bosch Appliances manual ICP-CC488| Installation Guide, Programming Sheets, En, Installer Code

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 103
Image 103
Installer Code

ICP-CC488 Installation Guide 25.0

Programming Sheets

 

 

EN 103

Installer Code

Location

181 to 184

Refer to page 54

Default

1 2 3 4

User Codes

Location

185 to 264

Refer to page 54

User Code 1

 

Locations 185 to 189

Default

 

2 5 8 0

10

User Code 2

 

Locations 190 to 194

Default

 

15 15 15 15

2

User Code 3

 

Locations 195 to 199

Default

 

15 15 15 15

2

User Code 4

 

Locations 200 to 204

Default

 

15 15 15 15

2

User Code 5

 

Locations 205 to 209

Default

 

15 15 15 15

2

User Code 6

 

Locations 210 to 214

Default

 

15 15 15 15

2

User Code 7

 

Locations 215 to 219

Default

 

15 15 15 15

2

User Code 8

 

Locations 220 to 224

Default

 

0 15 15 15

3

Radio Code 9

Locations 225 to 229

Default

 

15 15 15 15

2

Radio Code 10

Locations 230 to 234

Default

 

15 15 15 15

2

Radio Code 11

Locations 235 to 239

Default

 

15 15 15 15

2

Radio Code 12

Locations 240 to 244

Default

 

15 15 15 15

2

Radio Code 13

Locations 245 to 249

Default

 

15 15 15 15

2

Radio Code 14

Locations 250 to 254

Default

 

15 15 15 15

2

Radio Code 15

Locations 255 to 259

Default

 

15 15 15 15

2

Radio Code 16

Locations 260 to 264

Default

 

15 15 15 15

2

User Code Priority Levels

 

 

 

 

 

 

Priority

Description

 

 

0

 

Arm/disarm

 

 

1

 

Arm only

 

 

2

 

Arm/disarm and Open/Close Reports

 

3

 

Arm only and Close Report

 

4

 

Arm/disarm and code to isolate

 

6

 

Arm/disarm, code to isolate, and

 

 

 

Open/Close Reports

 

 

8

 

Arm/disarm and Master Code functions

 

10

 

Arm/disarm, Master Code functions, and

 

 

Open/Close Reports

 

 

12

 

Arm/disarm, Master Code functions, and

 

 

code to isolate

 

 

14

 

Arm/disarm, Master Code functions, code

 

 

to isolate, and Open/Close Reports

 

Day Alarm Zones

Location

 

265

 

Refer to page 56

Default

0

1

Zone 1

 

 

2

Zone 2

 

 

4Zone 3

8 Zone 4

EOL Resistor Value

Location

266

Refer to page 56

0No EOL resistor

11K (brown, black, red)

2 1K5 (brown, green, red)

3 2K2 (red, red, red)

4 3K3 (orange, orange, black, brown) 1%

5 3K9 (orange, white, red)

6 4K7 (yellow, white, red)

7 5K6 (green, blue, red)

8 6K8 (blue, grey, black, brown) 1%

9 10K (brown, black, orange)

10 12K (brown, red, orange)

11 22K (red, red, orange)

12 Reserved

13 Reserved

14 Split EOL (3K3/6K8) with tamper (1K)

15 Split EOL (3K3/6K8) 1% resistors

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 103
Image 103
Bosch Appliances ICP-CC488| Installation Guide, Programming Sheets, En, Installer Code, User Codes, Day Alarm Zones