ICP-CC488 Installation Guide 5.0

System Functions

 

 

EN 26

Table 23: Telephone Monitor Mode Indications

Zone LED

Dialing Event

1Telephone line seized

2Dialing phone number

3Handshake received

4Data is being transmitted

5Kiss-off received

None

Telephone line released

To turn Telephone Monitor Mode on:

1.Enter the Installer Code and press [6][AWAY]. Three beeps sound.

2.Press and hold [9] until two beeps sound. A Test Report is sent.

To turn Telephone Monitor Mode off:

Enter the Installer Code and press [6][AWAY]. Two beeps sound.

You must exit from Telephone Monitor

Mode to resume normal operations.

5.1.8Walk Test Mode

Walk Test Mode allows you to test detection devices to ensure they are functioning correctly. Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to Section 3.11 Isolating Zones for more information. Use Locations 383 and 384 to enable Walk Test Mode Reports (refer to Section 15.2).

To enter Walk Test Mode:

1.Enter the Installer Code and press [7][AWAY]. Three beeps sound and the STAY and AWAY indicators flash. The codepad beeps once per sec when Walk Test Mode is active.

2.Unseal and seal the zones to be tested.

The codepad sounds one long beep and the horn speaker sounds one short beep each time a zone is sealed or unsealed.

3.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators are extinguished. The system returns to the disarmed state.

5.1.9Event Memory Recall Mode

This function allows you to play back the last 40 system events that occurred. Event Memory Recall Mode reports all alarms and each arming or disarming of the system and helps with troubleshooting system faults. The events are displayed using the codepad indicators.

To enter Event Memory Recall Mode:

Enter the Installer Code and press [8][AWAY]. Three beeps sound. The events are played back by the codepad indicators in reverse chronological order.

Example

If the events occurred in the following order:

Table 24: Event Sequence

Sequence Event

1System armed in AWAY Mode

2Alarm in Zone 3

3Alarm in Zone 4

4System disarmed

The alarm memory plays back in this order:

Table 25: Event Memory Playback

Sequence

 

Indication

Event

1

 

All indicators off

System disarmed

 

 

except MAINS

 

2

 

Zone 4 and AWAY

Alarm in Zone 4

 

 

indicators light

 

3

 

Zone 3 and AWAY

Alarm in Zone 3

 

 

indicators light

 

4

 

AWAY indicator

System armed in

 

 

lights

AWAY Mode

Each event is indicated by a beep and a lit indicator. Resetting a disarmed 24-Hour Alarm is indicated by a beep only.

After the last event, three beeps sound to indicate the end of playback. You can stop the replay at any time by pressing [AWAY].

If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.

If the control panel is powered down, the memory of all events is saved.

If a ICP-CC488 Control Panel is partitioned, only ten events per area play back.