ICP-CC488 Installation Guide 24.0

Specifications

 

 

EN 100

Select Option 1 (Send Test Reports only if the system is armed) in Location 428 (refer to Section 18.5 Consumer Options 1 on page 82) and then set the Test Report Time to be in the middle of the day. During Monday to Friday when the premises are generally open and the system is disarmed, a Test Report is not sent. On the weekend, the premises are closed and the system armed, so a Test Report is sent at the programmed time to verify the operation of the dialer.

At first glance, this may not seem to be significant, but by doing a few sums you can see where savings are possible.

Assume that the customer wants, needs, or has Test Reports programmed for once per day with Opening and Closing reports. In this scenario, at least three phone calls are made each weekday, one call on Saturday, and one call on Sunday.

By using the ICP-CC488 Control Panel you can eliminate five calls per week. Over one week, you save your customer $1.25 and over one year you save them $65.00.

Not a bad saving, but remember these figures are for local calls only.

Now assume a control room with 1000 customers sending the same reports. It can expect to receive 884,000 phone calls ($221,000 assuming local calls) just for reporting Opening, Closing, and Test reports over a twelve month period.

If you use the ICP-CC488 Control Panel, you can cut the calls to 624,000 per year (at a value of $156,000 assuming local calls), a saving of $65,000. If we now assume that for each call one line is printed on the logging printer, and that one page is filled every 60 calls. You can save 4333 sheets of paper per year and at approximately $45 per box, this becomes a considerable saving.

As you can see using the ICP-CC488 Control Panel saves you money, saves your customer money, and helps to conserve our natural resources. In fact, the only organization that doesn’t like this feature is Telecom.

24.0Specifications

24.1Warranty Statement

Bosch Security Systems, Inc. warrants this product to be free from defects in material and workmanship for a period of three years from the date of manufacture as indicated by the date stamp or the serial number on the product.

Defective units returned by the purchaser at their own expense during this period will be repaired or replaced at the option of the manufacturer. The repair or replacement will be free of charge provided that the defects were not incurred during shipping or handling, or the damage was not due to causes beyond the control of Bosch Security Systems, Inc., such as lightning, excessive voltage, mechanical shock, or damage arising out of abuse, alteration, or improper application of the equipment.

24.2Specifications

Table 65: Specifications

Temperature Range

0oC to +45 oC

 

(+32 oF to +113 oF)

Humidity

10% to 95%

Power Source

TF008 Plug Pack –

 

240 V/18 VAC @ 1.3 A

Standby Current

65 mA

Current Draw In

115 mA

Alarm Condition

 

Current Draw In

105 mA

Alarm Condition With

 

Codepad

 

Backup Battery

6.5 Ah/12 VDC rechargeable

 

sealed lead acid battery

Dimensions (case,

306 mm x 262 mm x 84 mm

packed in carton)

(12.05 in. x 10.31 in. x 3.31 in.)

Weight

2.5 kg (5.51 lbs.)

Supplier Code

N771

New Zealand

 

Telepermit

 

ICP-CC488

PTC 211/98/083

24.3Software Version Number

Refer to Section 7.4.9 Command 999 – Display the Panel Type or Software Version Number for more information.

24.4New Zealand Telepermit Notes

The grant of a telepermit for a device does not indicate Telecom acceptance of responsibility for the correct operation of the device under all operating conditions.

This equipment shall not be used in any manner that could constitute a nuisance to other Telecom customers.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 100
Image 100
Bosch Appliances ICP-CC488 manual Specifications, Warranty Statement, Software Version Number, New Zealand Telepermit Notes