Bosch Appliances ICP-CC488 manual System Functions, 5.1Installer Code Functions

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 22
Image 22
System Functions

ICP-CC488 Installation Guide 5.0

System Functions

 

 

EN 22

To delete a remote radio User Code:

1.Enter the Master Code and press [1][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the user number (9 to 16) you want to delete and press [AWAY].

Two beeps sound and the corresponding zone indicators light. Refer to Table 18 on page 21.

3.Press [STAY] to delete the User Code.

Two beeps sound and the STAY and AWAY indicators are extinguished.

4.Repeat Steps 1 to 3 to delete another remote radio User Code.

This function is automatically terminated if you do not press a button within 60 sec or if you press [AWAY].

One long beep indicates that you selected an incorrect user number.

5.0 System Functions

This section explains more advanced features, such as Installer Code, Master Code, and hold-down functions that are required for testing and regular maintenance of the system.

5.1Installer Code Functions

Installer Code functions allow the installer to perform various system tests and tasks without knowing a Master Code.

To access the required Installer Code function, enter the Installer Code and corresponding function digit, and press [AWAY]. The Installer Code functions are listed in Table 19 on page 22.

You can access these functions only when the system is disarmed.

Table 19: Installer Code Functions

Function Description

0Add/delete RF wireless devices (Refer to Section 5.1.1)

1Set the number of days until the first Test Report

(Section 5.1.2)

2Change domestic telephone numbers (Section 5.1.3)

3Change the Telco arm/disarm sequence (Section 5.1.4)

4Set STAY Mode 2 zones (Section 5.1.5)

5Satellite Siren (EDMSAT) Service Mode (Section 5.1.6)

6Turn Telephone Monitor Mode on and off (Section 5.1.7)

7Walk Test Mode (Section 5.1.8)

8Event Memory Recall Mode (Section 5.1.9)

5.1.1Add or Delete RF Wireless Devices

The control panel can accept up to 16 wireless devices on any or all of the eight zones used by the system. It is possible to connect wireless PIRs, reed switches, and smoke detectors directly to the control panel. You can allocate multiple wireless devices to each zone (for example, you can allocate up to 16 wireless devices to Zone 1 and hard wire the remaining seven zones). Refer to Section 20.3 Default RF Device Mapping (Devices 1 to 8) and Section 20.4 Default RF Device Mapping (Devices 9 to 16) for more information.

To program an RF wireless device:

1.Enter the Installer Code and press [0][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the RF device number (1 to 16) you want to change and press [AWAY].

Two beeps sound and the corresponding codepad indicators light to show the RF device number you selected.

3.Enter the nine-digit RF ID number found on the back of the RF device and press [AWAY].

Two beeps sound and the STAY and AWAY indicators are extinguished.

4.Repeat Steps 1 to 3 to add another device.

This function is automatically terminated if you do not press a button within 60 sec or if you press [AWAY].

One long beep indicates that you selected an incorrect user number.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 22
Image 22
Bosch Appliances manual System Functions, 5.1Installer Code Functions, ICP-CC488| Installation Guide