ICP-CC488 Installation Guide 19.0

Partitioning

 

 

EN 86

19.4.1Zone Allocations for Areas 1 and 2

Location

502 to 517

 

 

 

 

Location

Default

Zone 1 LED – Area 1 Codepad

502

0

Zone 2 LED – Area 1 Codepad

503

0

Zone 3 LED – Area 1 Codepad

504

0

Zone 4 LED – Area 1 Codepad

505

0

Zone 5 LED – Area 1 Codepad

506

0

Zone 6 LED – Area 1 Codepad

507

0

Zone 7 LED – Area 1 Codepad

508

0

Zone 8 LED – Area 1 Codepad

509

0

Zone 1 LED – Area 2 Codepad

510

0

Zone 2 LED – Area 2 Codepad

511

0

Zone 3 LED – Area 2 Codepad

512

0

Zone 4 LED – Area 2 Codepad

513

0

Zone 5 LED – Area 2 Codepad

514

0

Zone 6 LED – Area 2 Codepad

515

0

Zone 7 LED – Area 2 Codepad

516

0

Zone 8 LED – Area 2 Codepad

517

0

 

 

 

0

Not mapped for this LED

 

1

A zone is mapped to this LED

 

You can enable or disable the zone allocations for Area 1 and Area 2. For example, if the location 507 is set to “0”, the zone LED of Area 1 is not mapped.

Detailed Example

In the following example, Zones 1, 2, 3, and 4 are allocated to Area 1 to appear as zones 1, 2, 3 and 4. Zones 1, 5, 6, 7, 8 are allocated to Area 2 to appear as zones 1, 5, 6, 7, and 8. Programming the same zone into more than one area specifies that zone as a common zone.

Figure 18: Area 1 Codepad Display

Area 1 Zone Allocations

Locations 502 to 509: 1 2 3 4 0 0 0 0

Figure 19: Area 2 Codepad Display

Area 2 Zone Allocations

Locations 510 to 517: 1 0 0 0 5 6 7 8

19.5User Code Allocations

Location 534 to 549

 

Location

Default

User Code 1

534

0

User Code 2

535

0

User Code 3

536

0

User Code 4

537

0

User Code 5

538

0

User Code 6

539

0

User Code 7

540

0

User Code 8

541

0

User Code 9

542

0

User Code 10

543

0

User Code 11

544

0

User Code 12

545

0

User Code 13

546

0

User Code 14

547

0

User Code 15

548

0

User Code 16

549

0

Locations 534 to 549 are used to assign each User Code to one or two area areas of a partitioned ICP- CC488 Control Panel. Enter a value from 0 to 3 into each of these locations to assign the User Code holder to the areas it must operate (refer to Table 61). You can allocate multiple User Codes to the same area.

Table 61: User Code Allocations

Option Description

0Not allocated to an area

1

Allocated to Area 1

2

Allocated to Area 2

3Allocated to Area 1 and Area 2

19.6Setting Up and Programming Codepads for Partitioning

Only the CP5 Area Addressable (CP500A) and CP5 Master Partitioned (CP500P) codepads can be used with a partitioned ICP-CC488 Control Panel.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 86
Image 86
Bosch Appliances ICP-CC488 User Code Allocations, Setting Up and Programming Codepads for Partitioning, Detailed Example