5.2.6Setting STAY Mode 2 Zones

ICP-CC488 Installation Guide 5.0

System Functions

 

 

EN 30

4.Press [STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

Example

If you want to automatically divert all unanswered incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter:

[2 5 8 0 3][AWAY][1][AWAY][STAY] [1 6 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]

You can suspend the telco arming sequence at any time. To disable the telco arming sequence:

Enter your Master Code and press [3][AWAY][1] [AWAY][STAY][4][AWAY].

To program the telco disarming sequence:

1.Enter your Master Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [2][AWAY] to change the telco disarming sequence.

Three beeps sound.

If a telco disarming sequence is already programmed, the sequence is displayed one digit at a time using the remote codepad indicators. Refer to Table 30 on page 29 for the indicators and their meanings.

If no telco disarming sequence is programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is displayed.

3.Enter the desired call forward disable sequence. For example, program [# 6 1 #] to disable the call forward – no answer sequence, or [# 2 1 #] to disable the call forward – immediate sequence.

When you program a # in the telco arm sequence, enter [STAY][2].

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the telco disarming sequence at any time. To disable the telco disarming sequence:

Enter your Master Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

5.2.6Setting STAY Mode 2 Zones

This function allows the Master Code holder to select the zones that are isolated automatically when the system is armed in STAY Mode 2.

To arm the system in STAY Mode 2, press and hold

[0]until two beeps sound. Refer to Section 5.4.3 or Section 3.5 Arming The System in STAY Mode 2 for more information.

To set STAY Mode 2 zones:

1.Enter your Master Code and press [4][AWAY]. Three beeps sound and the STAY indicator flashes.

2.Enter the number of the zone you want to automatically isolate and press [STAY]. The corresponding zone indicator flashes.

3.Repeat Step 2 to select each zone.

As each zone is selected to be isolated, the corresponding zone indicator flashes. If you make a mistake, enter the incorrect zone number and press [STAY]. This zone is no longer selected to be isolated and the zone indicator is extinguished.

This function does not work on a partitioned ICP-CC488 Control Panel.

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

The indicators for the zones you selected and the STAY indicator are extinguished.

Example

If you want to select zones 2, 5, and 6, enter:

[2 5 8 0 4][AWAY][2][STAY][5][STAY][6][STAY] [AWAY]

You can disable all zones selected to be automatically isolated for STAY Mode 2 at any time. To disable STAY Mode 2 zones:

Enter your Master Code and press [4][AWAY] [AWAY].

5.2.7Turning Outputs On/Off

If an output is programmed for remote operation, you can turn the remote output on or off using this Master Code function or remotely using the Alarm Link Software.

To use this Master Code function, you must program one or more of the outputs with these Output Event Types:

Output 1 = Output Event Type 2,8 (page 74) Output 2 = Output Event Type 2,9 (page 74) Output 3 = Output Event Type 2,10 (page 74)

To turn an output on from the remote codepad:

1.Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of the output (1 to 3) and press [AWAY].

Three beeps sound and the output turns on.

3.Repeat Step 2 to turn on another output.

4.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators are extinguished.