Codepad Indicators

ICP-CC488 Installation Guide 2.0

Codepad Indicators

 

 

EN 10

1.2.3Zone Types

There are thirteen zone types to choose from when programming zones for the ICP-CC488 Control Panel. Refer to Section 14.3 Zone Programming for more information.

Table 2: Zone Types

Type

Description

Type

Description

0

Instant

8

24-Hour Holdup

1

Handover

9

24-Hour Tamper

2

Delay-1

10

Reserved

3

Delay-2

11

Keyswitch

4

Reserved

12

24-Hour Burglary

5

Reserved

13

24-Hour Fire

6

24-Hour Medical

14

Chime only

7

24-Hour Panic

15

Zone not used

2.0Codepad Indicators

2.1ICP-CP508W Eight Zone LED

Codepad

Figure 1: ICP-CP508W Eight Zone LED Codepad

The codepad is the communications interface between you and the alarm system. The codepad allows you to issue commands and offers visual and audible indications to guide you through general operation.

The codepad incorporates a number of indicators: eight zone indicators show the condition of each zone and four other indicators show general status. These indicators are described in Table 3 through Table 8 on pages 10 through 11.

Zone Indicators

Table 3: Zone Indicators

Indicator

 

Definition

On

 

The zone is unsealed.

Off

 

The zone is sealed.

Flashing fast

 

The zone is in alarm.

(0.25 sec. on/

 

 

0.25 sec. off)

 

 

Flashing slow

 

The zone is manually isolated.

(1 sec. on/1 sec. off)

 

 

STAY Indicator

The STAY indicator lights when the system is armed in STAY Mode 1 or STAY Mode 2. The STAY indicator flashes with the AWAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.

For more information, refer to:

Section 3.3 to arm the system in STAY Mode 1.

Section 14.3.5 to set zones to be automatically isolated in STAY Mode 1.

Section 3.5 to arm the system in STAY Mode 2.

Section 5.1.5 to use the Installer Code to set zones to be automatically isolated in STAY Mode 2.

Section 5.2.6 to use the Master Code to set zones to be automatically isolated in STAY Mode 2.

Table 4: STAY Indicator

Indicator

Definition

On

The system is armed in STAY

 

Mode 1 or STAY Mode 2.

Off

The system is not armed in STAY

 

Mode 1 or STAY Mode 2.

Flashing

Zone isolating mode or setting STAY

 

Mode 2 zones.

Flashing once

Day Alarm status on/off indicator

every 3 sec

 

AWAY Indicator

The AWAY indicator lights when the system is armed in AWAY Mode. The AWAY indicator flashes with the STAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.

Refer to Section 3.1 Arming the System in AWAY Mode for more information.

Table 5: AWAY Indicator

Indicator

Definition

On

The system is armed in AWAY Mode.

Off

The system is not armed in AWAY Mode.