ICP-CC488 Installation Guide 13.0

Access Codes

 

 

EN 55

Location 185 to 264

 

Location

Default

User Code 1

185

2

 

186

5

 

187

8

 

188

0

Priority Level

189

10

User Code 2

190 to 193

15

Priority Level

194

2

User Code 3

195 to 198

15

Priority Level

199

2

User Code 4

200 to 203

15

Priority Level

204

2

User Code 5

205 to 208

15

Priority Level

209

2

User Code6

210 to 213

15

Priority Level

214

2

User Code 7

215 to 218

15

Priority Level

219

2

User Code 8

220

0

 

221 to 223

15

Priority Level

224

3

User Code 9

225 to 228

15

Priority Level

229

2

User Code 10

230 to 233

15

Priority Level

234

2

User Code 11

235 to 238

15

Priority Level

239

2

User Code 12

240 to 243

15

Priority Level

244

2

User Code 13

245 to 248

15

Priority Level

249

2

User Code 14

250 to 253

15

Priority Level

254

2

User Code 15

255 to 258

15

Priority Level

259

2

User Code 16

260 to 263

15

Priority Level

264

2

13.3User Code Priority

The installer can assign one of ten different priority levels to a User Code. Each priority level allows or restricts a user from performing specific functions.

Table 47: Priority Levels

Priority

Description

Level

 

0

Arm/disarm

1

Arm only

2

Arm/disarm and Open/Close Reports

3

Arm only and Close Report

4

Arm/disarm and code to isolate

6

Arm/disarm, code to isolate, and Open/Close

 

Reports

8

Arm/disarm and Master Code functions

10

Arm/disarm, Master Code functions, and

 

Open/Close Reports

12

Arm/disarm, Master Code functions, and code

 

to isolate

14

Arm/disarm, Master Code functions, code to

 

isolate, and Open/Close Reports

Arm/Disarm

The user can arm and disarm the system. A Closing Report is sent only after a previous code with the ability to send an Opening Report disarms the system.

Arm Only

The user can arm the system but cannot disarm the system. A Closing Report is sent only after a previous code with the ability to send an Opening Report disarms the system.

Open/Close Reports

Open and Close Reports are sent to the monitoring station when the user disarms and arms the system, but only if Open/Close Reports is enabled in Locations 401 and 402 (refer to Section 15.13 Open/Close Reports on page 67).

Code To Isolate

If one or more User Codes include this option, the method of standard isolating is disabled and only a User Code with this option in its priority level can isolate zones before arming the system using the Code to Isolate method. Refer to Section 3.11 Isolating Zones on page 17 for more information.

When priority level 4, 6, 12, or 14 is assigned to any User Codes, the Standard Isolating method no longer operates. Only User Codes with a priority level of 4, 6, 12, or 14 can isolate zones using the Code to Isolate method.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 55
Image 55
Bosch Appliances ICP-CC488 manual User Code Priority, Priority Levels, Arm/Disarm, Arm Only, Open/Close Reports