| Access Codes |
|
|
EN 55
Location 185 to 264
| Location | Default |
User Code 1 | 185 | 2 |
| 186 | 5 |
| 187 | 8 |
| 188 | 0 |
Priority Level | 189 | 10 |
User Code 2 | 190 to 193 | 15 |
Priority Level | 194 | 2 |
User Code 3 | 195 to 198 | 15 |
Priority Level | 199 | 2 |
User Code 4 | 200 to 203 | 15 |
Priority Level | 204 | 2 |
User Code 5 | 205 to 208 | 15 |
Priority Level | 209 | 2 |
User Code6 | 210 to 213 | 15 |
Priority Level | 214 | 2 |
User Code 7 | 215 to 218 | 15 |
Priority Level | 219 | 2 |
User Code 8 | 220 | 0 |
| 221 to 223 | 15 |
Priority Level | 224 | 3 |
User Code 9 | 225 to 228 | 15 |
Priority Level | 229 | 2 |
User Code 10 | 230 to 233 | 15 |
Priority Level | 234 | 2 |
User Code 11 | 235 to 238 | 15 |
Priority Level | 239 | 2 |
User Code 12 | 240 to 243 | 15 |
Priority Level | 244 | 2 |
User Code 13 | 245 to 248 | 15 |
Priority Level | 249 | 2 |
User Code 14 | 250 to 253 | 15 |
Priority Level | 254 | 2 |
User Code 15 | 255 to 258 | 15 |
Priority Level | 259 | 2 |
User Code 16 | 260 to 263 | 15 |
Priority Level | 264 | 2 |
13.3User Code Priority
The installer can assign one of ten different priority levels to a User Code. Each priority level allows or restricts a user from performing specific functions.
Table 47: Priority Levels
Priority | Description |
Level |
|
0 | Arm/disarm |
1 | Arm only |
2 | Arm/disarm and Open/Close Reports |
3 | Arm only and Close Report |
4 | Arm/disarm and code to isolate |
6 | Arm/disarm, code to isolate, and Open/Close |
| Reports |
8 | Arm/disarm and Master Code functions |
10 | Arm/disarm, Master Code functions, and |
| Open/Close Reports |
12 | Arm/disarm, Master Code functions, and code |
| to isolate |
14 | Arm/disarm, Master Code functions, code to |
| isolate, and Open/Close Reports |
Arm/Disarm
The user can arm and disarm the system. A Closing Report is sent only after a previous code with the ability to send an Opening Report disarms the system.
Arm Only
The user can arm the system but cannot disarm the system. A Closing Report is sent only after a previous code with the ability to send an Opening Report disarms the system.
Open/Close Reports
Open and Close Reports are sent to the monitoring station when the user disarms and arms the system, but only if Open/Close Reports is enabled in Locations 401 and 402 (refer to Section 15.13 Open/Close Reports on page 67).
Code To Isolate
If one or more User Codes include this option, the method of standard isolating is disabled and only a User Code with this option in its priority level can isolate zones before arming the system using the Code to Isolate method. Refer to Section 3.11 Isolating Zones on page 17 for more information.
When priority level 4, 6, 12, or 14 is assigned to any User Codes, the Standard Isolating method no longer operates. Only User Codes with a priority level of 4, 6, 12, or 14 can isolate zones using the Code to Isolate method.