Example (Auto Step Enabled)

ICP-CC488 Installation Guide 7.0

Programming

 

 

EN 39

Example (Auto Step Enabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when auto step is enabled:

1.Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

2.Program the number by pressing:

[10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]

Example (Auto Step Disabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when auto step is disabled:

Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

To program the number, press:

[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 10 *

# 5 * # 5 * # 0 *]

Table 37: Command 965 Defaults

Location

Description

Default Value

Setting

032

Handshake Tone for Receiver 1

1

(Handshake Tone)

033

Transmission Format

4

(Domestic)

034 and 039

Subscriber ID Number

0, 0, 0, 0, 0, 1

(1 Beep)

392

Zone Status Reporting Options

2

(Receiver 2 only)

401 to 402

Open/Close Reports

11, 12

(Open/Close Reports)

403

Open/Close Reporting Options

2

(Receiver 2 only)

424 to 426

System Status – Access Denied

6, 7, 12

(Access Denied)

427

System Status Reporting Options

2

(Receiver 2 only)

428 to 434

Test Report Time

0, 0, 0, 0, 7, 1, 0

(Test Reports)

435

Test Reporting Dialer Options

1

(Receiver 1 only)

7.4.9Command 999 – Display the Panel Type or Software Version Number

When using the remote codepad, this command displays the version of the control panel. Visually determining which control panel your printed circuit board (PCB) is set to is difficult because various control panels use the same PCB.

4.Enter [9 6 0 #] to exit from Installer's Programming Mode.

Two sound and the system returns to the disarmed state.

If you are using the remote codepad, the STAY and AWAY indicators are extinguished to indicate the system is disarmed.

The codepad displays 8 to indicate the control panel software, ICP-CC488.

To display the control panel type or software version number:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. If you are using the remote codepad, the STAY and AWAY indicators flash to indicate you entered Installer’s Programming Mode.

2.Enter [9 9 9 #]. Two beeps sound.

If you are using the remote codepad, the codepad lights a zone indicator corresponding to the control panel type. Refer to Section 2.0 Codepad Indicators on page 10 for more information.

3.Press [#] to exit from this command and return to the Installer’s Programming Mode.

7.5Disable Factory Defaults

Location 900

Default 0

This feature prevents the control panel from manually restoring the default settings by the default button and prevents the use of a programming key to automatically download to the control panel when the system is disarmed.

Enter the default setting of 0 for Location 900 to restore the control panel to its default settings. Enter 15 for Location 900 to restrict the ability to restore the control panel to its default settings and to require the Installer Code for future control panel programming.

If the Installer Code is unknown, you must restore the control panel to your Bosch distributor for exchange. A nominal fee applies for this service.

The use of this feature is not recommended.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Page 39
Image 39
Bosch Appliances 7.5Disable Factory Defaults, ICP-CC488| Installation Guide, Programming, Example Auto Step Enabled