Bosch Appliances manual ICP-CC488| Installation Guide, Programming Sheets, En

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 107
Image 107
Manual background

ICP-CC488 Installation Guide 25.0

Programming Sheets

 

 

EN 107

Entry Guard Time for STAY Mode

Location

472 to 473

Refer to page 78

Default

 

0 0

Location 472

Increments of 1 sec (0 to 15 sec)

Location 473

Increments of 16 sec (0 to 240 sec)

Delay Alarm Reporting Time

Location

474 to 475

Refer to page 78

Default

 

0 0

Location 474

Increments of 1 sec (0 to 15 sec)

Location 475

Increments of 16 sec (0 to 240 sec)

 

 

 

 

Sensor Watch Time

Location

476 to 477

Refer to page 66

Default

 

0 0

Location 476

Increments of days (tens digit)

Location 477

Increments of days (units digit)

Codepad Lockout Time

Location

478

Refer to page 79

Default

0

Location 478

Increments of 10 sec

 

 

 

Siren Run Time

Location

479

Refer to page 79

Default

5

Location 479

Increments of 1 minute

Siren Sound Rate (Slow <- Sound -> Fast)

Location

480

Refer to page 79

Default

7

 

 

 

Auto Arming Pre-Alert Time

Location

481

Refer to page 79

Default

1

Location 481

Increments of 5 min

Auto Arming Time

Location

482 to 485

Refer to page 79

Default

 

0 0 0 0

Location 482

Hour of the day – tens digit

Location 483

Hour of the day – units digit

Location 484

Minute of the day – tens digit

Location 485

Minute of the day – units digit

Auto Disarming Time

Location

486 to 489

Refer to page 79

Default

 

0 0 0 0

Location 486

Hour of the day – tens digit

Location 487

Hour of the day – units digit

Location 488

Minute of the day – tens digit

Location 489

Minute of the day – units digit

Kiss-Off Wait Time

Location

490

Refer to page 80

Default

3

Location 490

Increments of 500 ms

Speaker Beep Volume

Location

 

491

 

Refer to page 80

Default

 

 

13

0

 

No beeps

 

 

15

Loudest beeps

 

 

System Options 1

Location

 

492

 

Refer to page 80

1Bosch Security Systems, Inc. smart lockout allowed

2 Horn speaker monitor

4 Strobe indications for radio arm/disarm

8Assign button 4 on transmitter to operate STAY Mode 1

System Options 2

Location

493

Refer to page 81

Default 0

1Codepad Panic to be silent

2 Codepad Fire to be silent

4 Codepad Medical to be silent

8 Access denied (code retries) to be silent

System Options 3

Location

494

Refer to page 81

1AC fail after 1 hour (disabled – after 2 min)

2 Ignore AC fail

4 Pulse count handover allowed

8 Handover delay to be sequential

System Options 4

Location

495

Refer to page 82

Default

0

 

1Panel to power up disarmed (if power reset)

2 Arm/disarm tracking on power up

4 Internal crystal to keep time

8 Night arm station, or RE005 installed

Consumer Options 1

Location

496

Refer to page 82

Default

0

 

1Test reports only when armed

2 Test report after siren reset

4 Auto arm in STAY Mode 1

8 STAY indicator to display Day Alarm status

Consumer Options 2

Location

497

Refer to page 83

1Codepad display extinguishes after 60 sec

2Single button arming allowed (AWAY/STAY Modes 1 and 2)

4Single button disarming allowed (STAY Modes 1 and 2)

8Alarm memory reset on disarm

Bosch Security Systems, Inc. 12/08 F01U089457-02