Programming Sheets

ICP-CC488 Installation Guide 25.0

Programming Sheets

 

 

EN 101

Disconnect this equipment immediately if it becomes physically damaged and arrange for its disposal or repair.

The transmit level from this device is set at a fixed level, so there may be circumstances where the performance is less than optimal. Before reporting such occurrences as faults, please check the line with a standard telepermitted telephone and do not report a fault if the telephone performance is satisfactory.

This device is equipped with pulse dialing while the Telecom standard is DTMF tone dialing. There is no guarantee that Telecom lines will always continue to support pulse dialing.

Use of dialing, when this equipment is connected to the same line as other equipment, may give rise to bell tinkle or noise and may also cause a false answer condition. If problems such as this occur, the user should not contact the Telecom Faults Service.

This equipment is set up to carry out test calls at pre-determined times. These test calls interrupt other calls that might be set up on the line at the same time. Discuss the timing set for these test calls with the installer.

The timing set for test calls from this equipment may be subject to drift. If this proves to be inconvenient and your calls are interrupted, discuss the problem of timing with the equipment installer. Do not report the matter as a fault to Telecom Faults Service.

This equipment shall not be set up to make automatic calls to the Telecom 111 Emergency Service.

This equipment should not be used under any circumstances that may constitute a nuisance to other Telecom customers.

In the event of any problem with this device, disconnect the system battery, AC MAINS supply, and the telephone line. The user must arrange with the supplier of the device for the necessary repairs.

If the matter is reported to Telecom as a wiring fault and the fault is proven to be due to this product, a call-out charge will be incurred.

24.5A-Tick

The ICP-CC488 Control Panel is designed to comply with A-Tick.

25.0Programming Sheets

25.1ICP-CC488 Programming Sheets

Primary Telephone Number for Receiver 1

Location

 

000 to 015

 

 

Refer to page 49

Default

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Secondary Telephone Number for Receiver 1

Location

 

016 to 031

 

 

Refer to page 49

Default

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

 

 

 

 

 

 

Handshake Tone for Receiver 1

Location

 

032

 

Refer to page 49

1HI-LO handshake (contact ID)

21400 Hz (Ademco TX @ 1900 Hz)

3 2300 Hz (Low Speed Sescoa)

4 No handshake

5 Pager

Transmission Format for Receiver 1

Location

033

Refer to page 50

1Contact ID

24 + 2 express

3 FSK 300 baud

4Domestic

5 Basic pager

6Reserved

7Reserved

8Reserved

The Basic Pager option supports only eight zones due to protocol limitations. If you use more than eight zones, this option is not recommended.

If you use the Zone 16, the 4 + 2 Express and FSK 300 Baud formats are not recommended because Zone 16 will be assigned as "0" and some receivers will not support this zone.

Subscriber ID Number For Receiver 1

Location

034 to 039

Refer to page 50

Default

0 0 0 0 0 0

Primary Telephone Number for Receiver 2

Location

 

040 to 055

 

 

Refer to page 49

Default

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

 

 

 

 

 

 

Secondary Telephone Number for Receiver 2

Location

 

056 to 071

 

 

Refer to page 49

Default

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Handshake Tone for Receiver 2

Location

 

072

 

Refer to page 49

1HI-LO handshake (contact ID)

21400 Hz (Ademco TX @ 1900 Hz)

3 2300 Hz (low speed Sescoa)

4 No handshake

5 Pager