Bosch Appliances ICP-CC488 manual 10.0Dialer Reporting Formats, 10.1Transmission Formats

Models: ICP-CC488

1 118
Download 118 pages 4.08 Kb
Page 43
Image 43
Dialer Reporting Formats

ICP-CC488 Installation Guide 10.0

Dialer Reporting Formats

 

 

EN 43

9.2Setting Up and Programming Domestic Reporting

Programming the control panel for domestic reporting is extremely simple when using the Installer’s Programming Command 965. Refer to Section 7.4.7 Command 965 – Set Up Domestic Dialing Format on page 38 for more information.

To set up the control panel for domestic dialing:

1.Enter the Installer Code and press [AWAY] to enter Installer’s Programming Mode.

Two beeps sound and the STAY and AWAY indicators flash.

2.Enter [9 6 5] and press [AWAY].

Two beeps sound. The control panel is now set up for Domestic Dialing Format.

3.Enter [9 6 0] and press [AWAY] to exit from Installer’s Programming Mode.

Two beeps sound and the STAY and AWAY indicators are extinguished. The system returns to the disarmed state.

4.To program your telephone numbers, enter your Master Code and press [2][AWAY].

Three beeps sound and the STAY and AWAY indicators flash.

If any telephone numbers are already programmed, they are displayed one digit at a time using the codepad indicators.

If no telephone numbers are programmed, two additional beeps sound after you enter this mode. These two beeps normally sound after the last digit of the last phone number is displayed.

5.Enter the digits for telephone number 1, one digit at a time.

As you enter each digit, the corresponding codepad indicator lights.

6.After you enter all the digits of the first telephone number, press [STAY][4] to insert a break between the first telephone number and the sec telephone number.

7.Repeat Step 6 for each additional phone number.

8.After the last digit of the last telephone number, press [AWAY] to exit from this mode.

Table 38: Domestic Dialing Digits

Digit

Number to

Digit

Number to

Required

Program

Required

Program

0

0

8

8

1

1

9

9

2

2

 

 

3

3

*

[STAY]1

4

4

#

[STAY]2

5

5

4 sec pause

[STAY]3

6

6

break

[STAY]4

7

7

15

[STAY]5

Example

To program two separate telephone numbers (9672

1777 and 9672 1233), enter the following sequence:

[2 5 8 0 2][AWAY][9 6 7 2 1 7 7 7][STAY] [4 9 6 7 2 1 2 3 3][AWAY]

You can cancel domestic dialing at any time (for example, you are moving and do not want the system to continue calling your work place or mobile phone).

To disable domestic dialing:

Enter your Master Code and press [2][AWAY][STAY][4][AWAY].

10.0Dialer Reporting Formats

10.1Transmission Formats

The ICP-CC488 Control Panel provides a number of transmission formats for its dialing and communication features. Program the transmission format for Receiver 1 in Location 033 and the transmission format for Receiver 2 in Location 073 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 50). The control panel is set at the factory to report in the Contact ID Format.

10.1.1Contact ID Format

Contact ID Format can identify hundreds of protection zones by their unique codes. This format provides a single-digit Event Qualifier and a three- digit Event Code that quickly identifies the reported condition.

In general, Contact ID Format is very simple because most of the Event Codes and Point ID Codes are predefined. The base station software usually can identify an alarmed zone by its Point ID Code and usually pays little attention to the Event Code.

Refer to Section 10.1.3 Alarm Link Options on page 44 for more information about the ICP-CC488 Point ID Codes.

Bosch Security Systems, Inc. 12/08 F01U089457-02