Example

To program RF wireless device number 3 whose 9- digit ID number is 000094946, enter

[1 2 3 4 0][AWAY][3][AWAY] [0 0 0 0 9 4 9 4 6][AWAY]

To delete an RF wireless device:

1.Enter the Installer Code and press [0][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the RF device number (1 to 16) you want to delete and press [AWAY].

Two beeps sound and the corresponding codepad indicators light to show the RF device number you selected.

3.Press [STAY] to delete the RF device.

Two beeps sound and the STAY and AWAY indicators are extinguished.

4.Repeat Steps 1 to 3 to delete another RF wireless device.

5.1.2Set the Number of Days until the First Test Report

This function determines when the system sends the first Test Report (Contact ID Event Code 602). If you do not use this Installer Code function, the first Test Report is sent to the base station receiver after the repeat interval programmed in Location 428 (refer to Section 15.28 Test Reporting Time). If you want the system to send the first Test Report sooner than the repeat interval, use this function to set when the first Test Report is sent.

To set the first Test Report:

1.Enter the Installer Code and press [1][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of days (1 to 15) until the first Test Report is sent and press [AWAY].

Two beeps sound and the STAY and AWAY indicators are extinguished. The system returns to the disarmed state.

Each time you enter Installer’s Programming Mode, the first Test Report time defaults back to the repeat interval set in Location 434.

The number of days decrements by one at 2400 hours as set in Locations 901 to 904 (refer to Section 17.16 System Time).

Example

If the repeat interval is set to 7 days, but you want the first Test Report to be sent in 2 days, enter:

[1 2 3 4 1][AWAY][2][AWAY]

5.1.3Change Domestic Phone Numbers

When the system is set up for domestic dialing, this function allows the installer to view and program the telephone numbers the system calls if an alarm occurs. Refer to Section 9.0 Domestic Dialing on page 42 for more information.

To change domestic phone numbers:

1.Enter the Installer Code and press [2][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

If no telephone numbers are programmed, they are displayed one digit at a time using the remote codepad indicators. Refer to Table 21 on page 24 for the indicators and their meanings.

If no telephone numbers are programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after you enter the last digit of the last phone number.

2.Enter the first phone number.

Each digit is displayed as you enter it.

3.If you are programming another phone number, press [STAY][4] to separate the end of one phone number and the beginning of the next.

If you are not programming other numbers, go to Step 5.

4.Repeat Steps 2 and 3 to program another phone number.

5.Press [AWAY] to exit from this mode.

Table 20: Domestic Dialing Digits

Digit

Number to

Digit

Number to

Required

Program

Required

Program

0

0

8

8

1

1

9

9

2

2

 

 

3

3

*

[STAY]1

4

4

#

[STAY]2

5

5

4 sec pause

[STAY]3

6

6

break

[STAY]4

7

7

15

[STAY]5

Example

If you want to program two separate telephone numbers (9672 1777 and 9672 1233), enter:

[1 2 3 4 2][AWAY][9 6 7 2 1 7 7 7][STAY] [4 9 6 7 2 1 2 3 3][[AWAY]

You can suspend domestic dialing at any time (for example, you are moving house and do not want the system to continue calling your work place or mobile phone).

To disable domestic dialing:

Enter the Installer Code and press [2][AWAY] [STAY][4][AWAY].