When you enter Installer’s Programming Mode, you are automatically positioned at Location 000, the first digit of the Primary Telephone Number for Receiver 1. The codepad indicators show the current data stored in this location.
Table 34: Codepad Indicators
Data |
|
| Zone Indicators |
|
|
| |||
Value | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | MAINS |
0
1X
2 |
| X |
3 |
| X |
4 |
| X |
|
|
|
5 |
| X |
|
|
|
6 |
| X |
7 |
| X |
|
|
|
8 |
| X |
9 | X | X |
10 |
|
| X |
11 | X |
| X |
12 | X |
| X |
13 | X |
| X |
|
|
|
|
14 | X |
| X |
15 |
| X | X |
To move to a different programming location:
Enter the location number and press [AWAY]. For example, press [3 4][AWAY] to automatically step you to the beginning of the Subscriber ID Number for Receiver 1. The data stored in the new location appears.
To move to the next location:
Press [AWAY].
For example, if you are currently positioned at Location 034, press [AWAY] to step to Location 035.
To move to the previous location:
Press [STAY].
For example, if you are positioned at Location 035, press [STAY] to step back to Location 034.
To change data in the current location:
Enter the new value (0 to 15) and press [STAY]. The data is stored and you remain positioned at the same location. The new value is displayed using the codepad indicators (for example, if you enter [1 4] and press [STAY], the Zone 4 and MAINS indicators are lit).
To exit from Installer’s Programming Mode:
Enter command [9 6 0] and press [AWAY]. Two beeps sound and the STAY and AWAY indicators are extinguished. The system returns to the disarmed state and is now ready for use.
Refer to Section 7.4 Installer’s Programming Commands on page 36 for more information about using Installer’s Programming Mode.
7.2Programming with the Programming Key
The CC891 Programming Key allows you to store or copy programming information from your control panel. After storing information in the programming key, you can easily program other
If you connect the programming key to the control panel when it is disarmed, the key automatically initiates a data transfer to the control panel’s memory.
If you have a new programming key, enter Installer’s Programming Mode, program the system as required, and then connect the programming key to the control panel.
To connect the programming key:
Locate the socket labeled PROGRAMMING KEY at the top of the printed circuit board (PCB) next to the Auxiliary Module socket (refer to Figure 24 on page 96). Observe the triangular markings on the PCB and align them with the markings on the programming key.
To copy data from the control panel data to the programming key:
1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode.
2.Enter [9 6 2 #].
Refer to Section 7.4.4 Command 962 – Copy the Control Panel Memory to the Programming Key on page 37 for more information.
3.Enter [9 6 0 #] to exit from Installer’s Programming Mode.
Two beeps sound and the system returns to the disarmed state. Before removing the programming key, wait 2 sec for the activity LED to return to its normal state. The programming key becomes your standard data pattern for future control panel programming.
If you enter Installer’s Programming Mode, insert a programming key, and then change the data in any location, the data for both the programming key and the control panel is changed at the same time.