Dialer Information

ICP-CC488 Installation Guide 11.0

Dialer Information

 

 

EN 48

10.2Basic Pager Display Information

The Pager format supports only eight zones.

Subscriber ID Number

This is the identification number of the control panel and is programmed in Locations 034 to 039 for Receiver 1 and Locations 074 to 079 for Receiver 2 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 50). The pocket pager displays only the last three digits of the Subscriber ID Number.

Zone Status

The zone status display shows you the status of each zone (1 to 8) of the control panel. Table 44 on page

48 describes each status number when displayed on a pocket pager.

Table 44: Zone Status Display

Status

Zone Description

0Zone normal

The zone is sealed.

1Alarm

The zone is unsealed and in alarm.

2Zone bypassed

A system operator manually isolated the zone. Refer to Section 3.11 Isolating Zones on page 17for information about manually isolating a zone(s) before arming the system. Refer to Section 15.3 Zone Status – Bypass Reports on page 65 for more information.

3Zone trouble

A zone was left unsealed after the end of Exit Time. Refer to Section 15.4 Zone Status – Trouble Reports on page 65for more information.

System Status

The system status information shown by four digits is defined in Figure 9 on page 47.

The first digit indicates whether the system is armed or disarmed.

The sec digit indicates if a codepad alarm was activated by the operator (refer to Section 3.7 Codepad Duress Alarm through Section 3.10 Codepad Medical Alarm on page 17 for more information).

The third digit indicates the status of the AC MAINS supply.

The fourth digit indicates whether a system fault occurred at the control panel (refer Section 3.12 Fault Analysis Mode on page 18 for more information.

11.0 Dialer Information

This section outlines the programming information required for the ICP-CC488 Control Panel when communicating with a base station receiver. These parameters specify the telephone numbers to call, transmission formats, handshake tones, and transmission speeds.

The control panel can report event information from two on-board dialers. The first dialer reports to Receiver 1 and the sec dialer reports to Receiver 2. You can program each dialer with two separate telephone numbers, handshake tone, reporting format type, and Subscriber ID Number.

Example

You can set up Dialer 1 to report in Domestic Dialing Format to Receiver 1 and set up Dialer 2 to report to a base station receiver in Contact ID Format only if Dialer 1 is unsuccessful.

To program a telephone number:

When programming a telephone number, you must program a 0 as a 10. Each location in the primary, secondary, and callback telephone numbers stores one digit of the telephone number.

You must insert a 0 at the end of a telephone number to indicate to the dialer the end of the telephone number is reached. The dialing sequence terminates when a 0 appears.

Example

To program the telephone number 9672 1055 as the Primary Telephone Number for Receiver 1, program the following sequence into Locations 000 to 015:

[9 6 7 2 1 10 5 5 0 0 0 0 0 0 0 0]

To enter a 4-sec pause in the dialing sequence, program a 13. A pause might be necessary when the dialer communicates through an old (slower) telephone exchange or when a PABX system is in place.

Example

To program the number 02 pause 9 672 1055, enter:

[10 2 13 9 6 7 2 1 10 5 5 0 0 0 0 0].

Table 45 on page 55 shows how to program the numbers, keys, and functions for a telephone number.

Bosch Security Systems, Inc. 12/08 F01U089457-02