Partitioning

ICP-CC488 Installation Guide 19.0

Partitioning

 

 

EN 84

19.0 Partitioning

The ICP-CC488 Control Panel includes the partitioning feature, which can effectively transform your single control panel into two separate areas. Normally, arming and disarming the system turns the entire system on or off. When the ICP-CC488 Control Panel is partitioned, you can arm or disarm an individual area without affecting the other area.

Partitioning is extremely useful when you want to secure sheds, dual occupancy dwellings, accessory dwellings, shops, and offices.

Only the CP5 Area Addressable (CP500A) codepad and the CP5 Master Partitioned (CP500P) codepad can be used in partitioned systems.

19.1CP500 Master Partitioned LED Codepad

Figure 17: ICP-CP500PW Master Partitioned Codepad

This codepad is only used on a partitioned ICP- CC488 Control Panel. The Master Partitioned LED codepad allows a user to operate both areas individually from the same codepad, without the need to operate individual areas from separate codepads.

The codepad is the communications interface between you and the alarm system. The codepad allows you to issue commands and offers visual and audible indications to guide you through general operation.

The codepad incorporates a number of indicators: eight zone indicators show the condition of each zone, eight area indicators show the area status, and four other indicators show general status. These indicators are described in detail in Section ICP- CP500PW Master Partitioned LED Codepad on page 12.

19.2Using Codepads in a Partitioned System

19.2.1Operating with a CP5 Area Addressable LED Codepad

The display and operations of a CP5 Area Addressable (CP500A) codepad in a partitioned system are exactly the same as the CP5 Eight Zone LED codepad, except that the commands issued from the codepad affect only the area to which the codepad is allocated. Refer to Section 3.0 System Operations on page 14 for more information.

Example

If the codepad is allocated to Area 2, only User Codes that are allocated to Area 2 can operate the codepad. If User Codes have access only to Area 1, entering the code at the Area 2 codepad does not work.

If you want to determine the area to which the codepad you are operating is allocated, hold down

[8].If Zone 1 lights, the codepad is allocated to Area 1. If Zone 2 lights, the codepad is allocated to Area 2. Refer to Section 5.4 Hold-Down Functions on page 32 for more information.

19.2.2Operating with a CP5 Master Partitioned Codepad

Operations using a CP5 Master Partitioned (CP500P) codepad in a partitioned system are the same as the CP5 Area Addressable codepad with one exception. All operations are related only to the lit Area Display. If the Area Display 2 is lit, the codepad displays information only for Area 2 (that is, all operations effect only Area 2). Refer to Section 3.0 System Operations on page 14 for more information.

To move from one area to the next:

1.Press [AWAY].

The next Area Display indicator lights (for example, if Area Display 1 is lit, pressing [AWAY] lights Area Display 2.

2.Press [AWAY] to toggle the display back to other Area Display indicator.

In the example, pressing [AWAY] again lights Area Display 1.

19.3Programming

Locations 500 and 501 apply only to a partitioned ICP-CC488 Control Panel.

These locations have up to four options. You can select any combination of these options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 7.3 Programming Option Bits on page 36 for more information.