Chapter 5 SNMP MIB Installation and Configuration

Tables and Groups

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

For example, to change the value for Constant Pump Current mode, use the following steps:

Step 1 Set the pump value using cerent15216EdfaPumpCfgConstPumpCurrent attribute.

a.Select pump 1.

b.Set the value.

Step 2 Repeat Step 1 for pump 2.

Step 3 Set the pump mode of operation using cerent15216EdfaPumpCfgControlMode attribute.

a.Select pump 1.

b.Set the mode.

Step 4 Repeat Step 3 for pump 2.

Example 5-7shows how to set the value for Constant Pump Current mode to be 200 mA and then set the mode to Constant Pump Current mode again for the settings to take effect.

Example 5-7 Changing Value for Constant Pump Current Mode

ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 1

200

ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 2

200

ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 1

constCurrent

ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 2

constCurrent

5.4.3 OverallStatusGroup Table

The cerent15216EdfaOverallStatusGroup table allows users to display the input and output of the ONS 15216 EDFA2 amplifier. Table 5-8 on page 5-17describes cerent15216EdfaOverallStatusGroup table variables.

Cisco ONS 15216 EDFA2 Operations Guide