Chapter 4 Provisioning Using ASH and SNMP

 

Set Password

 

 

 

 

 

 

 

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

 

 

Table 4-1 Alarm Threshold Attribute Definitions (continued)

 

 

 

 

 

 

 

 

 

 

 

Variable

 

Maximum

 

 

 

 

Attribute

Definition

Syntax

Access

Description

 

 

 

 

 

 

 

 

 

 

cerent15216Edfa

Power bus

Integer

Read-write

Minimum allowable power bus DC

 

 

PowerBusDCVolt

minimum

(350 to

 

voltage. The default minimum power bus

 

 

ageMin

voltage

700, 400

 

voltage is set at –40 VDC. Valid entries

 

 

 

 

default)

 

are between 350 and 700 and are in

 

 

 

 

 

 

negative volts times 10. For example, if

 

 

 

 

 

 

the voltage required is –40 VDC, the

 

 

 

 

 

 

power bus setting is 400.

 

 

 

 

 

 

The power bus threshold has a 1.0V

 

 

 

 

 

 

tolerance and a 1.0V hysteresis. There is

 

 

 

 

 

 

a potential ±1.5V inaccuracy in the

 

 

 

 

 

 

ONS 15216 EDFA2 voltage

 

 

 

 

 

 

measurement. If the minimum threshold

 

 

 

 

 

 

is configured at 400 (-40 VDC), the

 

 

 

 

 

 

alarm will not raise until the voltage

 

 

 

 

 

 

measures below -39 VDC and will not

 

 

 

 

 

 

clear until the voltage measures above

 

 

 

 

 

 

-41 VDC.

 

 

 

 

 

 

 

 

 

 

cerent15216Edfa

Power bus

Integer

Read-write

Maximum allowable power bus DC

 

 

PowerBusDCVolt

maximum

(350 to

 

voltage. The default maximum power bus

 

 

ageMax

voltage

700, 570

 

voltage is set at –57 VDC. Valid entries

 

 

 

 

default)

 

are between 350 and 700 and are in

 

 

 

 

 

 

negative volts times 10. For example, if

 

 

 

 

 

 

the voltage required is –57 VDC, the

 

 

 

 

 

 

power bus setting is 570.

 

 

 

 

 

 

The power bus threshold has a 1.0V

 

 

 

 

 

 

tolerance and a 1.0V hysteresis. There is

 

 

 

 

 

 

a potential ±1.5V inaccuracy in the

 

 

 

 

 

 

ONS 15216 EDFA2 voltage

 

 

 

 

 

 

measurement. If the maximum threshold

 

 

 

 

 

 

is configured at 570 (-57 VDC), the

 

 

 

 

 

 

alarm will not raise until the voltage

 

 

 

 

 

 

measures above -58 VDC and will not

 

 

 

 

 

 

clear until the voltage measures below

 

 

 

 

 

 

-56 VDC.

 

 

 

 

 

 

 

 

4.9 Set Password

To restrict access to the ONS 15216 EDFA2, use the user passwd set command to change the default user password. The password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. With the exception of the administrator access level (read_write_admin), users can only modify their own passwords. For additional information on user levels, refer to Table 6-1 on page 6-1. Example 4-9displays the command.

Example 4-9 Changing Current User’s Password

ash:hostname:ONS15216 EDFA2> user passwd set

Cisco ONS 15216 EDFA2 Operations Guide