Table 5-6 cerent15216EdfaCfgGroup Variable Descriptions (continued)

 

 

Maximum

 

Variable

Syntax

Access

Description

 

 

 

 

cerent15216EdfaCLEI

Display String

Read-only

Indicates the factory setting of the

 

(0 to 10

 

Common Language Equipment

 

characters)

 

Identifier (CLEI) code (established by

 

 

 

Telcordia) of the Cisco

 

 

 

ONS 15216 EDFA2. This attribute

 

 

 

can be accessed but not changed by

 

 

 

the user.

 

 

 

 

cerent15216EdfaPowerBus

cerent15216Edfa

Read-write

Simplex for one power source (Bus

Mode

PowerBusMode

 

A) or duplex for redundant power

 

 

 

source (Bus A and Bus B) Power Bus

 

 

 

mode.

 

 

 

 

cerent15216EdfaPowerBus

Integer

Read-write

Minimum allowable power bus DC

DCVoltageMin

(350 to 700)

 

voltage. The default maximum power

 

 

 

bus voltage is set at –40 VDC. Valid

 

 

 

entries are between 350 and 700 and

 

 

 

are in negative volts times 10. For

 

 

 

example, if the voltage required is –40

 

 

 

VDC, the power bus setting is 400.

 

 

 

The power bus threshold has a 1.0V

 

 

 

tolerance and a 1.0V hysteresis. If the

 

 

 

minimum threshold is configured at

 

 

 

400 (-40 VDC), the alarm will not

 

 

 

raise until the voltage goes below -39

 

 

 

VDC and will not clear until the

 

 

 

voltage goes above -41 VDC.

 

 

 

 

cerent15216EdfaPowerBus

Integer

Read-write

Maximum allowable power bus DC

DCVoltageMax

(350 to 700)

 

voltage. The default maximum power

 

 

 

bus voltage is set at –57 VDC. Valid

 

 

 

entries are between 350 and 700 and

 

 

 

are in negative volts times 10. For

 

 

 

example, if the voltage required is –57

 

 

 

VDC, the power bus setting is 570.

 

 

 

The power bus threshold has a 1.0V

 

 

 

tolerance and a 1.0V hysteresis. If the

 

 

 

maximum threshold is configured at

 

 

 

570 (-57 VDC), the alarm will not

 

 

 

raise until the voltage goes above -58

 

 

 

VDC and will not clear until the

 

 

 

voltage goes below -56 VDC.

 

 

 

 

Use the snmp attribute set local cerent15216EdfaOpSaveConfig perform command to save changes.

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01