Chapter 8 Provisioning Using TL1

Set Date and Time

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

8.4 Set Date and Time

Use the ED-DATcommand (see “ED-DAT” section on page 9-16) to set the date and time. A time zone cannot be set using TL1. The time setting is restricted to universal coordinated time (UTC) according to the following syntax:

ED-DAT:[<tid>]::<ctag>::<utcdate>,<utctime>;

The utcdate and utctime entries must follow this format: yyyy-mm-dd,hh-mm-ss. See Example 8-4.

Example 8-4 Setting the Date and Time Using TL1

sidtidname:ONS15216 EDFA2> ED-DAT:::120::2002-04-18,02-24-55;

8.5 Set Power Bus Mode (Simplex or Duplex)

The ONS 15216 EDFA2 allows users to set a simplex (one power source–Bus A) or duplex (redundant power source–Bus A and Bus B) Power Bus mode. The default mode is duplex. Use the ED-ENVcommand (see “ED-ENV” section on page 9-18) to set the desired power bus mode according to the following syntax:

ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;

The pwrbusmode value can be SIMPLEX or DUPLEX. See Example 8-5.

Example 8-5 Setting the Power Bus Mode Using TL1

sidtidname:ONS15216 EDFA2> ED-ENV::ALL:121:::PWRBUSMODE=SIMPLEX;

8.6 Verify Amplifier Operational Status

To ensure that the amplifier is working correctly on the optical level, you must verify the amplifier operational status. Use the RTRV-DWDMcommand (see “RTRV-DWDM” section on page 9-48) to verify amplifier operational status according to the following syntax:

RTRV-DWDM:[<tid>]:<aid>:<ctag>; <sid> <date> <time>

M <ctag> COMPLD "<aid>:INPWRMICROW=<inputpoweruw>,INPWRDBM=<inputpowerdbm>,OUTPWRMILLIW=<outputpowermw

>,OUTPWRDBM=<outputpowerdbm>,PUMP1CTRLMODE=<pump1ctrlmode>,PUMP1CTRLVALUE=<pump1ctrlvalue>

,PUMP2CTRLMODE=<pump2ctrlmode>,PUMP2CTRLVALUE=<pump1ctrlvalue>,OVERALLGAIN=<gain>,PREATT=<

preatt>"

Example 8-6displays sample output of this command.

Example 8-6 Verifying the Amplifier Operations Status Using TL1

sidtidname:ONS15216 EDFA2> RTRV-DWDM::ALL:122;

sidtidname 2002-07-11 10:20:05

M122 COMPLD "1:INPWRMICROW=264,INPWRDBM=-1578,OUTPWRMILLIW=172,OUTPWRDBM=237,PUMP1CTRLMODE=GAINTEMP

,PUMP1CTRLVALUE=169,PUMP2CTRLMODE=GAINTEMP,PUMP2CTRLVALUE=169,OVERALLGAIN=169,PREATT=60"

;