CiscoONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter8 Provisioning Using TL1
Set Date and Time
8.4 Set Date and Time
Use the ED-DAT command (see ED-DAT section on page9-16) to set the date and time. A time zone
cannot be set using TL1. The time setting is restricted to universal coordinated time (UTC) according to
the following syntax:
ED-DAT:[<tid>]::<ctag>::<utcdate>,<utctime>;
The utcdate and utctime entries must follow this format: yyyy-mm-dd,hh-mm-ss. See Example 8-4.
Example8-4 Setting the Date and Time Using TL1
sidtidname:ONS15216 EDFA2> ED-DAT:::120::2002-04-18,02-24-55;
8.5 Set Power Bus Mode (Simplex or Duplex)
The ONS 15216 EDFA2 allows users to set a simplex (one power sourceBus A) or duplex (redundant
power sourceBus A and Bus B) Power Bus mode. The default mode is duplex. Use the ED-ENV
command (see ED-ENV section on page 9-18) to set the desired power bus mode according to t he
following syntax:
ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;
The pwrbusmode value can be SIMPLEX or DUPLEX. See Example 8-5.
Example8-5 Setting the Power Bus Mode Using TL1
sidtidname:ONS15216 EDFA2> ED-ENV::ALL:121:::PWRBUSMODE=SIMPLEX;
8.6 Verify Amplifier Operational Status
To ensure that the amplifier is working correctly on the optical level, you must verify the amplifier
operational status. Use the RTRV-DWDM command (see RTRV-D WDM section on pag e 9-48) to
verify amplifier operational status according to the following syntax:
RTRV-DWDM:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:INPWRMICROW=<inputpoweruw>,INPWRDBM=<inputpowerdbm>,OUTPWRMILLIW=<outputpowermw
>,OUTPWRDBM=<outputpowerdbm>,PUMP1CTRLMODE=<pump1ctrlmode>,PUMP1CTRLVALUE=<pump1ctrlvalue>
,PUMP2CTRLMODE=<pump2ctrlmode>,PUMP2CTRLVALUE=<pump1ctrlvalue>,OVERALLGAIN=<gain>,PREATT=<
preatt>"
Example 8-6 displays sample output of this command.
Example8-6 Verifying the Amplifier Operations Status Using TL1
sidtidname:ONS15216 EDFA2> RTRV-DWDM::ALL:122;
sidtidname 2002-07-11 10:20:05
M 122 COMPLD
"1:INPWRMICROW=264,INPWRDBM=-1578,OUTPWRMILLIW=172,OUTPWRDBM=237,PUMP1CTRLMODE=GAINTEMP
,PUMP1CTRLVALUE=169,PUMP2CTRLMODE=GAINTEMP,PUMP2CTRLVALUE=169,OVERALLGAIN=169,PREATT=60"
;