Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Example 9-43 RTRV-TH-ENV Command and Response

Amp01:ONS15216 EDFA2> RTRV-TH-ENV:Amp01:ALL:123::PWRBUSMIN;

Amp01 2002-07-16 14:24:29

M123 COMPLD "PWR-A,ENV:PWRBUSMIN,,,420"

;

Table 9-47 RTRV-TH-ENV Syntax Description

Parameter

Syntax

Description

 

 

 

date

yyyy-mm-dd

Date of origination of TL1 message.

 

 

 

time

hh:mm:ss

Time of origination of TL1 message.

 

 

 

aid

 

PWR-A, PWR-B, and ALL have same input effect.

 

 

 

 

PWR-A

Affecting Power Bus A (or both A and B).

 

 

 

 

PWR-B

Affecting Power Bus B.

 

 

 

 

ALL

Any or all of the preceding (command input only).

 

 

 

threshholdtype

 

Type of threshold that is to be retrieved. A null value is

and

 

equivalent to ALL. Possible to specify values for one or more

thresholdvalue

 

of the following:

pairs

 

 

PWRBUSMIN

Power bus minimum voltage

 

 

 

(cerent15216EdfaPowerBusDCVoltageMin).

 

 

thresholdvalue can be between 350 and 700, with default of

 

 

400, in units of –10 VDC.

 

 

 

 

PWRBUSMAX

Power bus maximum voltage

 

 

(cerent15216EdfaPowerBusDCVoltageMax).

 

 

thresholdvalue can be between 350 and 700, with default of

 

 

570, in units of –10 VDC.

 

 

 

9.7.41 RTRV-TH-EQPT

CommandRTRV-TH-EQPT

Retrieves general threshold values for the ONS 15216 EDFA2.

SyntaxRTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,]; <sid> <date> <time>

M <ctag> COMPLD

"<aid>:<thresholdtype>,,,<thresholdvalue>"

;

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

9-57

 

 

 