Cisco Systems 15216 EDFA2 Summary of Autonomous Alarms and Messages, Symbol Meaning Description

Models: 15216 EDFA2

1 280
Download 280 pages 30.04 Kb
Page 151
Image 151

Chapter 9 TL1 Commands

Summary of Autonomous Alarms and Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 9-3 TL1 Notation Symbols

Symbol

Meaning

Description

 

 

 

[ ]

Optional expression

Square brackets indicate the parameters are optional. An

 

 

optional parameter means that if a user inputs an empty

 

 

field for an optional parameter, then a default value (or a

 

 

default action) will be substituted automatically in the

 

 

transmitted input field. The default value, or null value,

 

 

is defined in the parameter descriptions of the messages.

 

 

 

< >

Variable expression

Angle brackets enclose one or more variable items in the

 

 

command line, e.g., <date>, <time>, <aid>, etc.

 

 

Italics are used to note variables in paragraph text, e.g.,

 

 

date, time, aid, etc.

 

 

 

+

More than one time

Plus signs indicate that preceding symbol or group of

 

 

symbols (enclosed in parentheses) may occur one or

 

 

more times.

 

 

 

text

Indent of three spaces

An indented line indicates an entry of three spaces in the

 

 

command line.

 

 

 

9.5 Summary of Autonomous Alarms and Messages

Table 9-4summarizes the ONS 15216 EDFA2 autonomous alarms.

Table 9-4 TL1 Autonomous Alarms

 

Condition

 

Access

Notification

Service

TL1 Autonomous

Type

Condition Descriptor

Identifier

Code

Effect

Message

(condtype)

(conddescr)

(aid)

(ntfcncde)

(srveff)

 

 

 

 

 

 

REPT ALM DWDM1

LOS

Loss Of Signal (input power)

1

MJ

SA

REPT ALM DWDM1

GAIN

Gain Out Of Range

1

MJ

SA

REPT ALM DWDM1

LPOUT

Loss Of Output Power

1

MJ

SA

REPT ALM ENV

PWRBUSA

Power Bus A (voltage)

PWR-A

MN/CR2

 

 

Alarm

 

 

 

 

 

 

 

 

 

REPT ALM ENV

PWRBUSB

Power Bus B (voltage)

PWR-B

MN/CR2

 

 

Alarm

 

 

 

 

 

 

 

 

 

REPT ALM EQPT

CTMP

Case Temperature Out Of

EQPT

MN

NSA

 

 

Range

 

 

 

 

 

 

 

 

 

REPT ALM EQPT

LCRNT1

Excessive Pump1 Current

EQPT

MN

NSA

 

 

 

 

 

 

REPT ALM EQPT

LCRNT2

Excessive Pump2 Current

EQPT

MN

NSA

 

 

 

 

 

 

REPT ALM EQPT

LTMP1

Excessive Pump1

EQPT

MN

NSA

 

 

Temperature

 

 

 

 

 

 

 

 

 

REPT ALM EQPT

LTMP2

Excessive Pump2

EQPT

MN

NSA

 

 

Temperature

 

 

 

 

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

9-3

 

 

 

Page 151
Image 151
Cisco Systems 15216 EDFA2 manual Summary of Autonomous Alarms and Messages, Symbol Meaning Description