Chapter 5 SNMP MIB Installation and Configuration

Tables and Groups

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 5-10 cerent15216EdfaPumpStatusEntry Variable Descriptions (continued)

 

 

Maximum

 

Variable

Syntax

Access

Description

 

 

 

 

cerent15216EdfaPumpStatusDCVoltage

Integer (0 to

Read-only

DC voltage (*10V)

 

9999)

 

 

 

 

 

 

cerent15216EdfaPumpStatusInPoweruW

Integer (0 to

Read-only

Input power (*10

 

99999)

 

microW)

 

 

 

 

cerent15216EdfaPumpStatusInPowerdBm

Integer

Read-only

Input power (*100

 

(–999999 to

 

dBm)

 

 

 

 

999999)

 

 

 

 

 

 

cerent15216EdfaPumpStatusOutPowermW

Integer (0 to

Read-only

Output power (*100

 

999999)

 

mW)

 

 

 

 

cerent15216EdfaPumpStatusOutPowerdBm

Integer

Read-only

Output power (*100

 

(–99999 to

 

dBm)

 

 

 

 

99999)

 

 

 

 

 

 

cerent15216EdfaPumpStatusGain1

Integer (–9999

Read-only

Gain (*10 dB)

 

to 9999)

 

 

 

 

 

 

1.The value of the cerent15216EdfaPumpStatusGain variable should always be around 23 dB. This variable is the internal amplifier module gain. The cerent15216EdfaPumpStatusGain variable should not be confused with the cerent15216EdfaConstGainOverallGain variable that is used to set the gain of the ONS 15216 EDFA2. The cerent15216EdfaPumpStatusGain is the value of the gain of the amplification module only, it does not take into account the VOA (variable optical attenuator) attenuation. If you try to calculate the gain using the values of the PumpStatusOutPowerdBm – PumpStatusInPowerdBm you will not get the exact PumpStatusGain value. A more complex calculation is required to get the gain value. It needs to take ASE (amplified spontaneous emission) into account. This is often called the amplifier noise. This variable will be more dominant when the input power to the amplifier is low.

5.4.6AlarmEntry Table

The cerent15216EdfaAlarmEntry table is used to display alarm status. The associated table command provides a summary of all alarms. Table 5-11describes the cerent15216EdfaAlarmEntry table variables.

Table 5-11 cerent15216EdfaAlarmEntry Variable Descriptions

 

 

Maximum

 

Variable

Syntax

Access

Description

 

 

 

 

cerent15216EdfaAlarmIndex

cerent15216EdfaIndex

Not

A unique value to

 

 

Accessible

identify this entry.

 

 

 

 

cerent15216EdfaAlarmID

AutonomousType

Read-only

The alarm this entry

 

 

 

refers to.

 

 

 

 

cerent15216EdfaAlarmPriority

cerent15216EdfaAlarmPriority

Read-only

The priority of this

 

 

 

alarm.

 

 

 

 

cerent15216EdfaAlarmState

cerent15216EdfaAlarmState

Read-only

The reporting state of

 

 

 

this alarm.

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

5-19

 

 

 

Page 81
Image 81
Cisco Systems 15216 EDFA2 manual AlarmEntry Table, cerent15216EdfaAlarmEntry Variable Descriptions