Others

External Control (only for

SR-HD1700)

This unit can be controlled using a PC, etc. by connecting them with an RS-232C or LAN cable.

RS-232C Specifications

Pin layout

 

 

 

Mode

:

Non-synchronous

 

 

 

 

 

 

 

 

1

5

Character length

:

8 bits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parity check

: Odd

 

 

 

 

 

 

 

 

 

 

 

 

6

9

 

Start bit

:

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop bit

:

1

 

 

 

 

 

 

 

 

 

 

PIN No.

Signal

Operation

 

Direction of signal

 

 

 

 

 

 

 

 

 

 

 

Data rate

:

9600 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

TxD

Transmit data

 

This unit h PC

Bit configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parity check

3

RxD

Receive data

 

This unit i PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

GND

Signal grounding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D0

 

D1

 

D2

D3

D4

D5

D6

D7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting bit

 

 

 

 

 

 

 

 

Stopping bit

Memo:

When using the Serial Command Connector, the cable to be used should be an RS-232C interface cable (straight type, 3 m or shorter).

During command transmission, a minimum interval of 50 ms is required between each command.

During command transmission, do not send the next command until the ACK (refer to “System Commands” (A page 100) ) or response (refer to “Response Commands” (A page 100) ) for each command is received.

The recommended maximum waiting time for the ACK or response for each command is as follows.

ACK

:

About 50 ms

Response

:

About 5 seconds

 

 

 

LAN Connection

To use a LAN connection, run the IP settings in “NETWORK SETTING(only for SR-HD1700)” (A page 90) . Connect by specifying 1111 for the port.

During command transmission, a minimum interval of 100 ms is required between each command.

92