Chapter 8 Provisioning Using TL1

Set Alarm Thresholds

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

sidtidname 2002-07-11 11:16:10

M125 COMPLD "EQPT:MAXCTMP,,,65"

"EQPT:MAXCTMPHYST,,,5"

"EQPT:MINCTMP,,,10"

"EQPT:MINCTMPHYST,,,2"

;

To set the alarm thresholds, use the SET-TH-DWDMand SET-TH-EQPTcommands (see

“SET-TH-DWDM” section on page 9-61and “SET-TH-EQPT” section on page 9-63). Alarm threshold attributes are described in Table 8-1.

Table 8-1 Alarm Threshold Attribute Definitions

 

Variable

 

Maximum

 

Attribute

Definition

Syntax

Access

Description

 

 

 

 

 

LOSTH

Loss of signal

Integer

Read-write

Alarm notifies operations personnel if

 

(input power)

(–3100 to

 

the optical input signal of the

 

threshold

–1500)

 

ONS 15216 EDFA2 drops below a

 

 

 

 

level that impacts proper operation of

 

 

 

 

optical network. Set this attribute at a

 

 

 

 

value that is appropriate for the

 

 

 

 

intended application so that the alarm

 

 

 

 

condition is meaningful. Consult with

 

 

 

 

the Cisco TAC to determine the

 

 

 

 

threshold value for your application.

 

 

 

 

As a guideline, Cisco recommends

 

 

 

 

setting the threshold value at 3 dBm

 

 

 

 

below the current input power level of

 

 

 

 

the amplifier. Valid entries are between

 

 

 

 

–3100 and –1500 dBm times 100. For

 

 

 

 

example, if the total input power of the

 

 

 

 

amplifier is –24 dBm and the loss of

 

 

 

 

input power threshold required is –27

 

 

 

 

dBm, the loss of input power alarm

 

 

 

 

threshold is –2700.

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

8-7

 

 

 

Page 143
Image 143
Cisco Systems 15216 EDFA2 manual Losth, Alarm Threshold Attribute Definitions