Cisco Systems 15216 EDFA2 manual Example 4-8 Displaying the Alarm Thresholds

Models: 15216 EDFA2

1 280
Download 280 pages 30.04 Kb
Page 54
Image 54

Chapter 4 Provisioning Using ASH and SNMP

Set Alarm Thresholds

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Figure 4-1 ONS 15216 EDFA2 Front Panel

Fiber

Fiber

Status

 

 

input

output

 

Alarm

port

port

LEDs

 

out

-48V A

 

POWER

 

-48V B

 

 

FAIL

CISCO ONS 15216

ALARM OUT

 

 

RS-232

 

 

 

 

LAN

 

 

LOS

 

 

R A

 

 

 

R B

71176

-48V A

Fiber

Power

RS-232

LAN port

-48V B

RET A

output

level

(EIA/TIA-232) LAN LEDs

RET B

 

monitor

warning

 

 

 

 

port

 

 

 

 

Alarms are reported for the following conditions:

Loss or degradation of electrical power

Laser pump overheating, excessive pump current

Loss or degradation of optical input

Alarms can be connected to a network operations center (NOC) network management system (NMS) via a network element miscellaneous discrete input and/or office alarm panel/system.

For a full description of alarm threshold command attributes, refer to Chapter 5, “SNMP MIB

Installation and Configuration” or Chapter 6, “ASH Commands.”

To display the alarm thresholds, use the snmp table display local cerent15216EdfaCfgGroup command (Example 4-8). This command returns the current alarm threshold default values.

Example 4-8 Displaying the Alarm Thresholds

ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaCfgGroup

CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCfgGroup ::=

{

cerent15216EdfaCfgSaved = false; cerent15216EdfaLpoutSetpoint = 0; cerent15216EdfaLpoutDeviation = 200; cerent15216EdfaLpoutHysteresis = 100; cerent15216EdfaLOSThreshold = -2600; cerent15216EdfaLOSHysteresis = 100; cerent15216EdfaCtmpMin = -5; cerent15216EdfaCtmpMinHysteresis = 1; cerent15216EdfaCtmpMax = 65; cerent15216EdfaCtmpMaxHysteresis = 1; cerent15216EdfaCLEI = ""; cerent15216EdfaPowerBusMode = duplex; cerent15216EdfaPowerBusDCVoltageMin = 410; cerent15216EdfaPowerBusDCVoltageMax = 560;

};

To set the alarm thresholds, use the snmp row set local cerent15216EdfaCfgGroup command. After this command is entered, the user is prompted to modify each attribute, row by row, until all attributes are set. Alarm threshold attributes are described in Table 4-1 on page 4-7.

Cisco ONS 15216 EDFA2 Operations Guide

4-6

78-16033-01

 

 

Page 54
Image 54
Cisco Systems 15216 EDFA2 manual Example 4-8 Displaying the Alarm Thresholds