Chapter 3 Installation

Communications

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

3.5.5.1 LAN Connection Procedure

Use the following procedure to configure the module to accept SNMP, CLI, and TL1 commands via its RJ-45 LAN port:

Step 1 The ONS 15216 EDFA2 IP address is factory set at 0.0.0.0. The IP address must be set before the ONS 15216 EDFA2 can be accessed via the Ethernet port. See “Set IP Address” section on page 4-3.

Step 2 Connect ONS 15216 EDFA2 to the network via the module LAN port.

Use a straight-through Cat5 Ethernet cable with RJ-45 connectors to connect to a LAN, or use a cross-over cable if connecting directly to a PC.

Step 3 At a terminal or workstation, open the Telnet application.

Note To send CLI and TL1 commands over IP, a Telnet client is required. For SNMP management over IP, a generic SNMP manager is required.

Step 4 Connect to the ONS 15216 EDFA2 using the module’s IP address.

If you do not specify a port number, the ONS 15216 EDFA2 responds in the shell that the

ONS 15216 EDFA2 is set to (TL1 is the default shell). Specify port number 8023 to access through the ASH shell or port number 3083 to access through the TL1 shell.

The ONS 15216 EDFA2 login screen appears. See “Log In via RS-232(EIA/TIA-232) Port Using HyperTerminal” section on page 4-1for the login procedure in ASH shell and “Log In via RS-232(EIA/TIA-232) Port Using HyperTerminal” section on page 8-1for the login procedure in TL1 shell.

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

3-15

 

 

 

Page 47
Image 47
Cisco Systems 15216 EDFA2 manual LAN Connection Procedure