Chapter 5 SNMP MIB Installation and Configuration

Retrieving Information

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

5.6.4 Case Temperature

5.6.4.1 Case Temperature Value

Command

snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp

Syntax Description snmp attribute get local cerent15216EdfaPumpStatusAmbientTemp pump#

Displays case temperature value (where pump# is the pump number).

The following command displays the temperature value (where pump# is the pump number) and other pump status data:

snmp row display local cerent15216EdfaPumpStatusAmbientTemp pump# command

The cerent15216EdfaPumpStatusAmbientTemp attribute of the cerent15216EdfaPumpStatusEntry display command shows the case temperature (Example 5-13).

Example 5-13 cerent15216EdfaPumpStatusEntry Display Command

ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaPumpStatusEntry 1

CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaPumpStatusEntry ::=

{

cerent15216EdfaPumpStatusPumpNum = 1; cerent15216EdfaPumpStatusLaserChipTemp = 260; cerent15216EdfaPumpStatusLaserChipTempSetpoint = 260; cerent15216EdfaPumpStatusLaserTECCurrent = 20; cerent15216EdfaPumpStatusLaserPower = 8503; cerent15216EdfaPumpStatusLaserCurrent = 17010; cerent15216EdfaPumpStatusAmbientTemp = 2272; cerent15216EdfaPumpStatusDCVoltage = 52; cerent15216EdfaPumpStatusInPoweruW = 250; cerent15216EdfaPumpStatusInPowerdBm = -600; cerent15216EdfaPumpStatusOutPowermW = 5000; cerent15216EdfaPumpStatusOutPowerdBm = 1700; cerent15216EdfaPumpStatusGain = 220;

};

Refer to Table 5-10 on page 5-18for information about all of the parameters in the cerent15216EdfaPumpStatusEntry table.

5.6.4.2 Case Temperature Alarm Threshold

5.6.4.2.1 CtmpMin

Command

snmp attribute get local cerent15216EdfaCtmpMin

Syntax Description snmp attribute get local cerent15216EdfaCtmpMin

This command displays minimum case temperature alarm threshold.

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

5-27

 

 

 

Page 89