FINAL DRAFT - CISCO CONFIDENTIAL
8-10
CiscoONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter8 Provisioning Using TL1
Set Password
8.9 Set Password
To restrict access to the ONS 15216 EDFA2, use the ED-PID command (see ED-PID section on
page 9-20) to change the default user password according to the following syntax:
ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>;
Note that the password must be a string of up to 10 characters, where at least 2 are non-alphabetic
characters and at least 1 is a special character. See Example8-9.
Example8-9 Changing Current User’s Password Using TL1
sidtidname:ONS15216 EDFA2> ED-PID::CISCO15:130::OLDPW,NEWPW;
Note The default user name for the administrator level is CISCO15 with no default password.
MINCTMPHYST Minimum
case
temperature
hysteresis
Integer
(0 to 10)
Read-write Used to set the amount that the case
temperature of the module must rise
above the minimum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that
the alarm condition clears when the
input is stable. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends that the hysteresis value
be set at 1°C. Valid entries are between
0 and 10°C. Setting this value to 0
disables this option.
Table8-1 Alarm Threshold Attribute Definitions (continued)
Attribute Variable
Definition Syntax Maximum
Access Description