Table 8-1 Alarm Threshold Attribute Definitions (continued)

 

 

 

 

 

 

 

 

 

 

 

Variable

 

Maximum

 

 

 

Attribute

Definition

Syntax

Access

Description

 

 

 

 

 

 

 

 

 

MINCTMPHYST

Minimum

Integer

Read-write

Used to set the amount that the case

 

 

 

case

(0 to 10)

 

temperature of the module must rise

 

 

 

temperature

 

 

above the minimum case temperature

 

 

 

hysteresis

 

 

alarm level before the alarm is cleared.

 

 

 

 

 

 

Set the hysteresis at a value that is

 

 

 

 

 

 

appropriate for the application so that

 

 

 

 

 

 

the alarm condition clears when the

 

 

 

 

 

 

input is stable. Consult with the Cisco

 

 

 

 

 

 

TAC to determine the correct value for

 

 

 

 

 

 

your application. As a guideline, Cisco

 

 

 

 

 

 

recommends that the hysteresis value

 

 

 

 

 

 

be set at 1°C. Valid entries are between

 

 

 

 

 

 

0 and 10°C. Setting this value to 0

 

 

 

 

 

 

disables this option.

 

 

 

 

 

 

 

8.9 Set Password

To restrict access to the ONS 15216 EDFA2, use the ED-PIDcommand (see “ED-PID” section on page 9-20) to change the default user password according to the following syntax:

ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>;

Note that the password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character. See Example 8-9.

Example 8-9 Changing Current User’s Password Using TL1

sidtidname:ONS15216 EDFA2> ED-PID::CISCO15:130::OLDPW,NEWPW;

Note The default user name for the administrator level is CISCO15 with no default password.