Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 9-10 ALW-MSG-ALL Syntax Description

 

 

 

 

Parameter

Syntax

Description

 

 

 

 

 

 

 

 

 

 

 

ntfncde

 

Notification code of the alarm or event that is to be

 

 

 

 

 

 

allowed (maps to cerent15216EdfaAlarmPriority for

 

 

 

 

 

 

active alarms). A null maps to none of the codes, i.e.,

 

 

 

 

 

 

with a null, all existing ntfncde inhibitions are kept

 

 

 

 

 

 

unchanged. Possible values are:

 

 

 

 

 

 

 

 

 

 

 

 

CR

Critical alarm.

 

 

 

 

 

 

 

 

 

 

 

 

MJ

Major alarm.

 

 

 

 

 

 

 

 

 

 

 

 

MN

Minor alarm.

 

 

 

 

 

 

 

 

 

 

 

 

NA

No alarm.

 

 

 

 

 

 

 

 

 

 

 

 

CL

Cleared alarm.

 

 

 

 

 

 

 

 

 

 

 

condtype

 

Condition type of the alarm or event that is to be allowed.

 

 

 

 

 

 

(Maps to cerent15216EdfaLogEventID.) ALL maps to

 

 

 

 

 

 

all types. A null maps to none of the types, i.e., with a

 

 

 

 

 

 

null, all existing condtype inhibitions are kept

 

 

 

 

 

 

unchanged. Possible condtype and corresponding

 

 

 

 

 

 

conddescr (in quotes) are:

 

 

 

 

 

 

 

 

 

 

 

 

LOS

“Loss of Signal” (input power) alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLpin).

 

 

 

 

 

 

 

 

 

 

 

 

GAIN

“Gain Out of Range” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmGain).

 

 

 

 

 

 

 

 

 

 

 

 

LPOUT

“Loss of Output Power” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLpout).

 

 

 

 

 

 

 

 

 

 

 

 

CTMP

“Case Temperature Out of Range” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmCtmp).

 

 

 

 

 

 

 

 

 

 

 

 

LCRNT1

“Excessive Pump1 Current” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLcrnt1).

 

 

 

 

 

 

 

 

 

 

 

 

LCRNT2

“Excessive Pump2 Current” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLcrnt2).

 

 

 

 

 

 

 

 

 

 

 

 

LTMP1

“Excessive Pump1 Temperature” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLtmp1).

 

 

 

 

 

 

 

 

 

 

 

 

LTMP2

“Excessive Pump2 Temperature” alarm

 

 

 

 

 

 

(cerent15216EdfaAlarmLtmp2).

 

 

 

 

 

 

 

 

 

 

 

 

POWERBUSA

“Power Bus A (voltage) Alarm”

 

 

 

 

 

 

(cerent15216EdfaAlarmPowerBusA).

 

 

 

 

 

 

 

 

 

 

 

 

POWERBUSB

“Power Bus B (voltage) Alarm”

 

 

 

 

 

 

(cerent15216EdfaAlarmPowerBusB).

 

 

 

 

 

 

 

 

 

 

 

 

CTRLMODE1

“Pump1 Control Mode Changed”

 

 

 

 

 

 

(cerent15216EdfaControlMode for

 

 

 

 

 

 

cerent15216EdfaPumpCfgPumpNumber=1).

 

 

 

 

 

 

 

 

 

 

 

 

CTRLMODE2

“Pump2 Control Mode Changed”

 

 

 

 

 

 

(cerent15216EdfaControlMode for

 

 

 

 

 

 

cerent15216EdfaPumpCfgPumpNumber=2).

 

 

 

 

 

 

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

 

 

 

 

 

 

 

9-10

 

 

 

 

78-16033-01

 

 

 

 

 

 

 

Page 158
Image 158
Cisco Systems 15216 EDFA2 manual Powerbusa, Powerbusb