CiscoONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter5 SNMP MIB Installation and Configuration
Retrieving Information

5.6.4.2.2 CtmpMax

snmp attribute get local cerent15216EdfaCtmpMax
Syntax Description snmp attribute get local cerent15216EdfaCtmpMax
This command displays maximum case temperature alarm threshold.
The following command displays case temperature alarm thresh old and other temperature data:
snmp row display local cerent15216EdfaCfgGroup command
This command is shown in Example 5-14.
Example5-14 cerent15216EdfaCfgGroup Display Command
ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaCfgGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = true;
cerent15216EdfaLpoutSetpoint = 0;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -3102;
cerent15216EdfaLOSHysteresis = 100;
cerent15216EdfaCtmpMin = -5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
cerent15216EdfaCLEI = "WMM4180BRA";
cerent15216EdfaPowerBusMode = duplex;
cerent15216EdfaPowerBusDCVoltageMin = 420;
cerent15216EdfaPowerBusDCVoltageMax = 700;
};
Refer to Table5-8 on page 5-17 for information about all of the parameters in
cerent15216EdfaOverallStatusGroup.
5.6.4.3 Case Temperature Alarm Hysteresis

5.6.4.3.1 CtmpMaxHysteresis

Command snmp attribute get local cerent15216EdfaCtmpMaxHysteresis
Syntax Description snmp attribute get local cerent15216EdfaCtmpMaxHysteresis
Displays maximum case temperature alarm hysteresis.
The cerent15216EdfaCtmpMaxHysteresis attribute in the cerent1 5216EdfaCfgGroup display command
shows the maximum case hysteresis temperature alarm threshold (Example 5-14 on page 5-28). Refer to
Table5-6 on p age 5-12 for information about all of the parameters in cerent15216EdfaCfgGroup.