Set Alarm Thresholds
cerent15216Edfa
CtmpMax
Maximum
case
temperature
Integer
(20 to 70,
65 default)
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 is at a level that may
impact proper operation of the optical
network. Set the maximum case
temperature at a value that is appropriate
for intended application and within
product specifications. Consult with the
Cisco TAC to determine the correct value
for your application. As a guideline,
Cisco recommends that maximum case
temperature value be set at 50°C. Valid
entries are between 20 and 70°C.
cerent15216Edfa
CtmpMaxHystere
sis
Maximum
case
temperature
hysteresis
Integer
(0 to 10,
1 default)
Read-write Used to set the amount that the case
temperature of module must drop below
the maximum case temperature alarm
level before the alarm is cleared. Set the
hysteresis at a value that is appropriate
for the application so that the alarm
condition clears when the input is stable.
Consult with the Cisco TAC to determine
the correct value for your application. As
a guideline, Cisco recommends setting
the value at 1°C. Valid entries are
between 0 and 10°C. Setting this value to
0 disables this option.
Table4-1 Alarm Threshold Attribute Definitions (continued)
Attribute Variable
Definition Syntax Maximum
Access Description