Chapter 4 Provisioning Using ASH and SNMP

Set Alarm Thresholds

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 4-1 Alarm Threshold Attribute Definitions (continued)

 

Variable

 

Maximum

 

Attribute

Definition

Syntax

Access

Description

 

 

 

 

 

cerent15216Edfa

Maximum

Integer

Read-write

Alarm notifies operations personnel if

CtmpMax

case

(20 to 70,

 

the case temperature of the

 

temperature

65 default)

 

ONS 15216 EDFA2 is at a level that may

 

 

 

 

impact proper operation of the optical

 

 

 

 

network. Set the maximum case

 

 

 

 

temperature at a value that is appropriate

 

 

 

 

for intended application and within

 

 

 

 

product specifications. Consult with the

 

 

 

 

Cisco TAC to determine the correct value

 

 

 

 

for your application. As a guideline,

 

 

 

 

Cisco recommends that maximum case

 

 

 

 

temperature value be set at 50°C. Valid

 

 

 

 

entries are between 20 and 70°C.

 

 

 

 

 

cerent15216Edfa

Maximum

Integer

Read-write

Used to set the amount that the case

CtmpMaxHystere

case

(0 to 10,

 

temperature of module must drop below

sis

temperature

1 default)

 

the maximum case temperature alarm

 

hysteresis

 

 

level before the alarm is cleared. Set the

 

 

 

 

hysteresis at a value that is appropriate

 

 

 

 

for the application so that the alarm

 

 

 

 

condition clears when the input is stable.

 

 

 

 

Consult with the Cisco TAC to determine

 

 

 

 

the correct value for your application. As

 

 

 

 

a guideline, Cisco recommends setting

 

 

 

 

the value at 1°C. Valid entries are

 

 

 

 

between 0 and 10°C. Setting this value to

 

 

 

 

0 disables this option.

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

4-9

 

 

 

Page 57
Image 57
Cisco Systems 15216 EDFA2 manual N a L D R a F T C I S C O C O N F I D E N T I a L