Table 9-28 REPT EVT DWDM / REPT EVT ENV / REPT EVT EQPT Syntax Description

 

 

Parameter

Syntax

Description

 

 

 

 

 

 

 

atag

0 - 999

An integer between 0 and 999 used as a sequence number

 

 

 

 

in autonomous messages .

 

 

 

 

 

 

 

aid

 

Possible values are:

 

 

 

 

 

 

 

 

1

Directly affecting the optical signal.

 

 

 

 

 

 

 

 

PWR-A

Affecting Power Bus A (or both A and B).

 

 

 

 

 

 

 

 

PWR-B

Affecting Power Bus B.

 

 

 

 

 

 

 

 

EQPT

General parameters of the ONS 15216 EDFA2 (not

 

 

 

 

directly affecting optical signal or power bus).

 

 

 

 

 

 

 

conddescr

 

Detailed text description of the event. The conddescr is 1

 

 

 

 

to 64 characters of ASCII text. See condtype below.

 

 

 

 

 

 

 

condtype

 

Condition type identifies the type of event (maps to

 

 

(ccm)

 

cerent15216EdfaLogEventID). Possible condtype and

 

 

 

 

corresponding conddescr (in quotes) are:

 

 

 

 

 

 

 

 

CTRLMODE1

“Pump1 Control Mode Changed”

 

 

 

(DWDM)

(cerent15216EdfaControlMode for

 

 

 

 

cerent15216EdfaPumpCfgPumpNumber=1).

 

 

 

 

 

 

 

 

CTRLMODE2

“Pump2 Control Mode Changed”

 

 

 

(DWDM)

(cerent15216EdfaControlMode for

 

 

 

 

cerent15216EdfaPumpCfgPumpNumber=2).

 

 

 

 

 

 

 

 

GAINCHGD

“Overall Gain Changed”

 

 

 

(DWDM)

(cerent15216EdfaConstGainOverallGain).

 

 

 

 

 

 

 

 

LOSHYSTCHGD

“LOS (loss of signal) Hysteresis Changed”

 

 

 

(DWDM)

(cerent15216EdfaLOSHysteresis).

 

 

 

 

 

 

 

 

LOSTHCHGD

“LOS (loss of signal) Threshold Changed”

 

 

 

(DWDM)

(cerent15216EdfaLOSThreshold).

 

 

 

 

 

 

 

 

LPOUTCHGD

“Loss of Output Power Setpoint Changed”

 

 

 

(DWDM)

(cerent15216EdfaLpoutSetpoint).

 

 

 

 

 

 

 

 

LPOUTDEVCHGD

“Lpout (loss of output power) Deviation Changed”

 

 

 

(DWDM)

(cerent15216EdfaLpoutDeviation).

 

 

 

 

 

 

 

 

LPOUTHYSTCHGD

“Lpout (loss of output power) Hysteresis Changed”

 

 

 

(DWDM)

(cerent15216EdfaLpoutHysteresis).

 

 

 

 

 

 

 

 

PREATTCHGD

“Pre-attenuation Changed”

 

 

 

(DWDM)

(cerent15216EdfaVariableGainPreAttenuation).

 

 

 

 

 

 

 

 

PWRBUSMAXCHGD

“Power Bus Max (voltage) Changed”

 

 

 

(EVN)

(cerent15216EdfaPowerBusDCVoltageMax).

 

 

 

 

 

 

 

 

PWRBUSMINCHGD

“Power Bus Min (voltage) Changed”

 

 

 

(EVN)

(cerent15216EdfaPowerBusDCVoltageMin).

 

 

 

 

 

 

 

 

PWRBUSMODE

“Power Bus Mode Changed”

 

 

 

(EVN)

(cerent15216EdfaPowerBusMode).

 

 

 

 

 

 

 

 

MAXCTMPCHGD

“Max Case Temperature Changed”

 

 

 

(EQPT)

(cerent15216EdfaCtmpMax).

 

 

 

 

 

 

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

 

 

 

 

 

 

 

78-16033-01

 

 

 

 

9-31

 

 

 

 

 

 