Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 9-40 RTRV-DWDM Syntax Description

Parameter

Syntax

Description

 

 

 

date

yyyy-mm-dd

Date of origination of TL1 message.

 

 

 

time

hh:mm:ss

Time of origination of TL1 message.

 

 

 

aid

 

1 and ALL have same input effect.

 

 

 

 

1

Directly affecting the optical signal.

 

 

 

 

ALL

Any or all of the preceding (command input only).

 

 

 

inputpoweruw

0 - 99999

Input power (signal) in units of 10 microW

 

 

(cerent15216EdfaInPoweruW).

 

 

 

inputpowerdbm

–999999 -

Input power (signal) in units of 100 dBm

 

999999

(cerent15216EdfaInPowerdBm).

 

 

 

outputpowermw

0 - 999999

Output power in units of 100 mW

 

 

(cerent15216EdfaOutPowermW).

 

 

 

outputpowerdbm

–99999 - 99999

Output power in units of 100 dBm

 

 

(cerent15216EdfaOutPowerdBm).

 

 

 

pump1ctrlmode,

 

Pump 1 or pump 2 control mode (maps to

pump2ctrlmode

 

cerent15216EdfaPumpCfgControlMode for the corresponding

 

 

pump). Possible values are:

 

 

 

 

GAINTEMP

Constant Gain Temperature Compensated mode (manufacturer

 

 

default) (cerent15216EdfaPumpCfgControlMode set to

 

 

constGainTempComp).

 

 

 

 

OPWR

Constant Output Power mode

 

 

(cerent15216EdfaPumpCfgControlMode set to

 

 

constOutputPower). A valid mode only for pump 2.

 

 

 

 

CRNT

Constant Pump Current mode

 

 

(cerent15216EdfaPumpCfgControlMode set to constCurrent).

 

 

 

 

PWR

Constant Pump Power mode

 

 

(cerent15216EdfaPumpCfgControlMode set to constPower).

 

 

 

 

IDLE

Pump is shut down (cerent15216EdfaPumpCfgControlMode

 

 

set to idle).

 

 

 

pump1ctrlvalue,

 

Pump 1 or pump 2 control value. This value’s interpretation

pump2ctrlvalue

 

depends on the control mode of the corresponding pump.

 

 

Possible values are:

 

 

 

 

0 - 650

Output power in units of 10 mW when mode is OPWR (gets

 

 

cerent15216EdfaPumpCfgConstOutPower).

 

 

 

 

0 - 300

Current value in mA when mode is CRNT (gets

 

 

cerent15216EdfaPumpCfgConstPumpCurrent).

 

 

 

 

0 - 100

Pump power in mW when mode is PWR (gets

 

 

cerent15216EdfaPumpCfgConstPumpPower).

 

 

 

gainmeasured

0 - 230

Value of gain in units of 10 dB when mode is GAINTEMP (gets

 

 

cerent15216EdfaConstGainOverallGainMeasured).

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

9-49

 

 

 

Page 197
Image 197
Cisco Systems 15216 EDFA2 manual ConstOutputPower. a valid mode only for pump, Idle, RTRV-DWDM Syntax Description