Chapter 5 SNMP MIB Installation and Configuration

Tables and Groups

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

5.4.1 CfgGroup Table

The cerent15216EdfaCfgGroup table is used to set or get alarm threshold configuration. The associated table command provides a summary of all alarm thresholds. See Table 5-6for variable definitions. For more information on alarm thresholds, see the “Set Alarm Thresholds” section on page 4-5.

Table 5-6 cerent15216EdfaCfgGroup Variable Descriptions

 

 

Maximum

 

Variable

Syntax

Access

Description

 

 

 

 

cerent15216EdfaCfgSaved

True Value

Read-only

Indicates whether the current

 

 

 

configuration has been saved.

 

 

 

 

cerent15216EdfaLpoutSetp

Integer

Read-only

Loss of pump output power set point

oint

(0 to 1000)

 

for the Lpout alarm (*10 mW).

 

 

 

This is set when the

 

 

 

cerent15216EdfaPumpCfgConstOutP

 

 

 

ower attribute is set for pump 2.

 

 

 

 

cerent15216EdfaLpoutDevi

Integer

Read-write

Amount that the output power must

ation

(0 to 1000)

 

deviate from the set point to set the

 

 

 

Lpout alarm (*100 dB).

 

 

 

 

cerent15216EdfaLpoutHyst

Integer

Read-write

Amount that the output power must

eresis

(0 to 1000)

 

move towards the set point before the

 

 

 

Lpout alarm is cleared (*100 dB).

 

 

 

 

cerent15216EdfaLOSThres

Integer

Read-write

Loss of signal threshold (*100 dBm).

hold

(–3100 to –1500)

 

 

 

 

 

 

cerent15216EdfaLOSHyster

Integer

Read-write

Amount above

esis

(0 to 1000)

 

cerent15216EdfaLOSThreshold that

 

 

 

the input signal must rise before the

 

 

 

Lpin alarm is cleared (*100 dB).

 

 

 

 

cerent15216EdfaCtmpMin

Integer

Read-write

Minimum allowable case temperature

 

(–10 to 10)

 

in degrees Celsius.

 

 

 

 

cerent15216EdfaCtmpMinH

Integer

Read-write

Amount above

ysteresis

(0 to 10)

 

cerent15216EdfaCtmpMin that the

 

 

 

case temperature must rise before the

 

 

 

Ctmp alarm is cleared in degrees

 

 

 

Celsius.

 

 

 

 

cerent15216EdfaCtmpMax

Integer

Read-write

Maximum allowable case temperature

 

(20 to 70)

 

in degrees Celsius.

 

 

 

 

cerent15216EdfaCtmpMax

Integer

Read-write

Amount below

Hysteresis

(0 to 10)

 

cerent15216EdfaCtmpMax that the

 

 

 

case temperature must drop before the

 

 

 

Ctmp alarm is cleared in degrees

 

 

 

Celsius.

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

5-12

78-16033-01

 

 