Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 9-17 ED-DWDM Syntax Description (continued)

Parameter

Syntax

Description

 

 

 

pump1ctrlvalue,

 

Pump 1 or pump 2 control value. This value’s interpretation

pump2ctrlvalue

 

depends on the control mode of the corresponding pump.

 

 

Command fails if control mode is GAINTEMP. Possible values

 

 

are:

 

 

 

 

0 - 650

Output power in units of 10 mW when mode is OPWR (sets

 

 

cerent15216EdfaPumpCfgConstOutPower). The default value

 

 

is 0.

 

 

 

 

0 - 300

Current value in mA when mode is CRNT (sets

 

 

cerent15216EdfaPumpCfgConstPumpCurrent). The default

 

 

value is 0. Must set pump 1 and pump 2 at the same time.

 

 

 

 

0 - 100

Pump power in mW when mode is PWR (sets

 

 

cerent15216EdfaPumpCfgConstPumpPower). The default

 

 

value is 0. Must set pump 1 and pump 2 at the same time.

 

 

 

gain

130 - 220

Value of gain in units of 10 dB when mode is GAINTEMP (sets

 

 

cerent15216EdfaConstGainOverallGain). The command fails

 

 

if in other modes.

 

 

 

preatt

10 - 100

Gain pre-attenuation value in units of 10 dB when mode is other

 

 

than GAINTEMP (sets

 

 

cerent15216EdfaVariableGainPreAttenuation).

 

 

 

9.7.11 ED-ENV

CommandED-ENV

Configures the ONS 15216 EDFA2 environmental (power bus) parameters.

SyntaxED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;

Example 9-13 ED-ENV Command

Amp01:ONS15216 EDFA2> ED-ENV:Amp01:ALL:123:::PWRBUSMODE=SIMPLEX;

Table 9-18 ED-ENV Syntax Description

Parameter

Syntax

Description

 

 

 

aid

PWR-A

PWR-A, PWR-B, and ALL have same input effect.

 

PWR-B

 

 

ALL

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

9-18

78-16033-01

 

 

Page 166
Image 166