FINAL DRAFT - CISCO CONFIDENTIAL
9-18
CiscoONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.11 ED-ENV
Command ED-ENV
Configures the ONS 15216 EDFA2 environmental (power bus) parameters.
Syntax ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;
Example 9-13 ED-ENV Command
Amp01:ONS15216 EDFA2> ED-ENV:Amp01:ALL:123:::PWRBUSMODE=SIMPLEX;
pump1ctrlvalue,
pump2ctrlvalue
Pump 1 or pump 2 control value. This values interpretation
depends on the control mode of the corresponding pump.
Command fails if control mode is GAINTEMP. Possible values
are:
0 - 650 Output power in units of 10 mW when mode is OPWR (sets
cerent15216EdfaPumpCfgConstOutPower). The default value
is 0.
0 - 300 Current value in mA when mode is CRNT (sets
cerent15216EdfaPumpCfgConstPumpCurrent). The default
value is 0. Must set pump 1 and pump 2 at the same time.
0 - 100 Pump power in mW when mode is PWR (sets
cerent15216EdfaPumpCfgConstPumpPower). The default
value is 0. Must set pump 1 and pump 2 at the same time.
gain 130 - 220 Value of gain in units of 10 dB when mode is GAINTEMP (sets
cerent15216EdfaConstGainOverallGain). The command fails
if in other modes.
preatt 10 - 100 Gain pre-attenuation value in units of 10 dB when mode is other
than GAINTEMP (sets
cerent15216EdfaVariableGainPreAttenuation).
Table9-17 ED-DWDM Syntax Description (continued)
Parameter Syntax Description
Table9-18 ED-ENV Syntax Description
Parameter Syntax Description
aid PWR-A
PWR-B
ALL
PWR-A, PWR-B, and ALL have same input effect.