Chapter 8 Provisioning Using TL1

Set Alarm Thresholds

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Table 8-1 Alarm Threshold Attribute Definitions (continued)

 

Variable

 

Maximum

 

Attribute

Definition

Syntax

Access

Description

 

 

 

 

 

MAXCTMP

Maximum

Integer

Read-write

Alarm notifies operations personnel if

 

case

(20 to 70)

 

the case temperature of the

 

temperature

 

 

ONS 15216 EDFA2 is at a level that

 

 

 

 

may impact proper operation of the

 

 

 

 

optical network. Set the maximum

 

 

 

 

case temperature at a value that is

 

 

 

 

appropriate for intended application

 

 

 

 

and within product specifications.

 

 

 

 

Consult with the Cisco TAC to

 

 

 

 

determine the correct value for your

 

 

 

 

application. As a guideline, Cisco

 

 

 

 

recommends that maximum case

 

 

 

 

temperature value be set at 50°C. Valid

 

 

 

 

entries are between 20 and 70°C.

 

 

 

 

 

MAXCTMPHYST

Maximum

Integer

Read-write

Used to set the amount that the case

 

case

(0 to 10)

 

temperature of module must drop

 

temperature

 

 

below the maximum case temperature

 

hysteresis

 

 

alarm level before the alarm is cleared.

 

 

 

 

Set the hysteresis at a value that is

 

 

 

 

appropriate for the application so that

 

 

 

 

the alarm condition clears when the

 

 

 

 

input is stable. Consult with the Cisco

 

 

 

 

TAC to determine the correct value for

 

 

 

 

your application. As a guideline, Cisco

 

 

 

 

recommends setting the value at 1°C.

 

 

 

 

Valid entries are between 0 and 10°C.

 

 

 

 

Setting this value to 0 disables this

 

 

 

 

option.

 

 

 

 

 

MINCTMP

Minimum

Integer

Read-write

Alarm notifies operations personnel if

 

case

(–10 to 10)

 

the case temperature of the

 

temperature

 

 

ONS 15216 EDFA2 drops below a

 

 

 

 

level that impacts proper operation of

 

 

 

 

the optical network. The minimum

 

 

 

 

case temperature should be set at a

 

 

 

 

value that is appropriate for the

 

 

 

 

intended application and within

 

 

 

 

product specifications. Consult with

 

 

 

 

the Cisco TAC to determine the correct

 

 

 

 

value for your application. As a

 

 

 

 

guideline, Cisco recommends that

 

 

 

 

minimum case temperature be set at

 

 

 

 

1°C. Valid entries are between –10 and

 

 

 

 

10°C.

 

 

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

8-9

 

 

 

Page 145
Image 145
Cisco Systems 15216 EDFA2 manual Maxctmphyst, Minctmp